HD-2X IRONCLAD Erasure Verification System ASSEMBLY
• Completely read through the instructions before
beginning assembly process.
• Do not open equipment chassis. Assembly only
requires access to exterior of units.
1A
Using a torx wrench, remove three bolts from the upper right and
lower right side of the HD-2X face plate. Save bolts for Step 2.
3A
3A. Attach stylus by slipping split ring from stylus tether onto one of the control head bolts before attaching
to mounting bracket and control head. 3B. Using the 3/16 allen wrench and 2 control head bolts, attach
touch screen and stylus to mounting bracket using center holes.
GarnerProducts.com
Tel: 916-784-0200
Fax: 916-784-1425
10620 Industrial Avenue Suite 100 Roseville, CA 95678
Package includes:
• Imaging device and
HDMI cable
• Touch Screen Control
Head
• 2 control head bolts
• Mounting bracket
3B
• Scanner, Stand
• Converter Cable
• DB9 cable
• A/C power cable
• 3/16 allen wrench
• T-20 torx wrench
• Stylus
2A
1B
Using a torx wrench and three bolts from Step 1, attach the imaging
device to the HD-2X.
See cable connecting instructions on page 2.