Download Print this page
Benchmark BSH1001 User Manual

Benchmark BSH1001 User Manual

Digital dry bath ii

Advertisement

Quick Links

Models BSH1001, BSH1002 and BSH1004 Users Manual
Benchmark's Digital Dry Baths are highly accurate, microprocessor controlled, dry block heating
units capable of heating one, two or four aluminum blocks or aluminum or glass pans. They provide
unsurpassed temperature uniformity and accuracy for heating microtubes, test tubes and other
small vessels, including microplates and slides. Each dry bath has a bright green LED display,
easy to set temperature and time controls and comes complete with a block lifter.
SPECIFICATIONS
Well size
Temperature range
Increments and display resolution 0.1˚C
Temperature uniformity
Temperature accuracy
Timer function / resolution
Size wxdxh (in.) / weight
Electrical 115/230VAC 50/60Hz
CAUTION: Hot surfaces, especially on the block, can cause serious injury or burns.
CAUTION: Do not put water or liquids into the well as shock, serious injury and death may occur.
CAUTION: Do not heat flammable or explosive substances as serious injury and death may occur.
Input Voltage Configuration
The dry bath has 2 RED SLIDE SWITCHES on the back. These can be set for either 115VAC input
or 230VAC input. Check the setting to be sure it matches your outlet power. Both switches must
be set to the same setting 115 or 230. Do not mix settings or dry bath damage will result. Also do
not plug the dry bath into a 230V outlet if the switch settings are 115 or damage will result. Once
these switches are set they should not be changed.
SET UP and OPERATION
Place the dry bath on a stable, flat surface away from air vents and any equipment exhaust vents.
Plug the dry bath into a properly grounded outlet of the correct voltage. Insert the block(s) into the
heating well using the block lifter. Caution: blocks may be hot! Using the switch on the back of
the unit, turn the power on. The dry bath will make a "beep" sound, illuminate each digit on the
display left to right and briefly illuminate the red and green lamps while it performs a unit test. After
the unit test, the display will begin showing the well temperature and the red heating lamp will flash.
Setting the Temperature
Use the Up and Down arrow buttons to increase or decrease the temperature setting. The
temperature can be set in tenths of a degree C. Once the temperature is set, press the
START/STOP button, the display will revert to showing the well temperature, the green Temp-Run
lamp will illuminate and the Heating lamp with flash until the set temperature has been reached.
The temperature setting is automatically remembered if power is turned off or if the power is lost.
(continued on next page)
Digital Dry Bath II
BSH1001
1 block
Amb.+5˚C to 150˚ C
+/-0.2˚C
+/-0.2˚C
off (untimed) or on to 999 minutes in 1 minute increments
7.9x9.1x3.2 (2.2kg)
100 watts
BSH1002
2 block
Amb.+5˚C to 150˚ C Amb.+5˚C to 130˚C
0.1˚C
+/-0.2˚C
+/0.2˚C
8.7x10.7x3.2 (2.5kg) 8.7x14.3x3.2 (3.5kg)
150 watts
BSH1004
4 block
0.1˚C
+/-0.2˚C
+/-0.2˚C
300 watts

Advertisement

loading

Summary of Contents for Benchmark BSH1001

  • Page 1 Digital Dry Bath II Models BSH1001, BSH1002 and BSH1004 Users Manual Benchmark’s Digital Dry Baths are highly accurate, microprocessor controlled, dry block heating units capable of heating one, two or four aluminum blocks or aluminum or glass pans. They provide unsurpassed temperature uniformity and accuracy for heating microtubes, test tubes and other small vessels, including microplates and slides.
  • Page 2 page 2 Using and Setting the Timer The dry bath has a built-in digital timer function that sounds a “beeping” alarm and turns off the heat when the set time has been reached. Press the Mode button to illuminate the Timer lamp and place the dry bath into the timer set mode. Use the Up and Down arrow buttons to set the desired time in one minute increments on the display.

This manual is also suitable for:

Bsh1002Bsh1004