Technical Specification - XPower FM-65B Owner's Manual

Rechargeable air circulator / misting fan
Table of Contents

Advertisement

Available languages

Available languages

PROBLEM
Machine does not
start
Unit runs but the
speed or the sound
is abnormal
Misting function is
abnormal
If troubleshooting does not resolve your problem, please contact XPOWER or other
parties authorized by XPOWER for further instructions.

Technical Specification

Atomization Specification
Misting Nozzle
FM-65B
0.3 mm (Marked 3010)
FM-65WB
/ FT-
0.3 mm (Marked 3010)
65WB
English - 14
POSSIBLE CAUSE
Low battery capacity.
Air inlet or air outlet is blocked.
Low battery capacity.
The water hose is blocked.
The atomization assembly is
blocked.
The water switch is off or no
water supply.
When the battery capacity
is 20% or lower, in order to
protect the battery, the preset
program will stop the machine
and prohibit the machine from
working again.
Charge the
Remove blockage.
When the battery capacity
is 20% or lower, in order to
protect the battery, the preset
program will stop the machine
and prohibit the machine from
working again.
Charge the
Remove blockage.
Remove blockage.
10: Atomization Assembly
Maintenance)
Check for water supply.
Max Mist Volume
5.9 L / h
7.5 L / h
SOLUTION
(See Page 6:
Battery.)
(See Page 6:
Battery.)
(See Page
Max Throw Distance
29.5 ft. / 9.0 m
29.5 ft. / 9.0 m

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fc-150bFc-125bFm-65wbFt-65wb

Table of Contents