Touch free deck-mounted single unit electronic faucet and soap dispenser (15 pages)
Summary of Contents for Stern TUBULAR 1000 Series
Page 1
INSTALLATION AND MAINTENANCE GUIDE TUBULAR 1000 SERIES TUBULAR 1000 SERIES WALL MOUNTED ELECTRONIC FAUCET WITH MIXER Tubular 1000 B Tubular 1000 E Tubular 1000 B Box Tubular 1000 E Box...
Page 2
I N DEX TECHNICAL DATA PACK CONTENTS 2 -3 PRE-INSTALLATION INFORMATION FAUCET INSTALLATION Tubular 1000 B and Tubular 1000 E 8-11 Tubular 1000 B Box and Tubular 1000 E Box SETTINGS ADJUSTMENT BATTERY REPLACEMENT INSTRUCTIONS To replace the battery at Tubular 1000 B and Tubular 1000 B Box models MAINTENANCE Filters cleaning instructions Care and cleaning of chrome and special finishes...
TE C H N I CA L DATA TUBULAR 1000 TUBULAR 1000 WALL MOUNTED ELECTRONIC WITH A WALL MOUNTED ELECTRONIC WITH A MIXER TO ADJUST THE TEMPERATURE 9V battery or 6 x 1.5 V AA batteries Power supply for battery versions: Power supply for electricity versions: 9V transformer Recommended water pressure:...
PAC K CON TEN TS TUBULAR 1000 B / 1000 E Spout and attachments (incl. electronic unit) Wall rosette Power splitter Tubular base M4x6 setscrew Allen key 2 x Solenoids and housings with filters and filter adaptors B V E R S I O N S E V E R S I O N S IP 67 Battery box Transformer...
Page 5
PAC K CON TEN TS TUBULAR 1000 B BOX / 1000 E BOX Spout and attachments (incl. electronic unit) 2 x Angle supports Wall rosette #6x1 1/2˝screws x 2 M4x6 screws x 4 Tubular base M4x6 screw Temporary Cable sleeve protective cover Power...
PRE-INSTALLATION INFO Check contents Separate all parts from the packaging and check each part with the pack contents section. Pay attention to the variations of the different models. Make sure all parts are accounted for before discarding any packaging material. If any parts are missing, do not attempt to install your electronic faucet until you obtain the missing parts.
FAUCE T I NSTAL L AT I ON Installation instructions for & & & TUBULAR 1000 B TUBULAR 1000 E Step 1 – Installing the faucet 1. Shut off the water supply. 2. Drill a hole (28 to 29 mm. ) at the place where you want to install the spout of the tap.
Page 8
FAUC ET IN STA LL AT IO N Step 2 - Connecting the water supply 1. Fit the flexible pipes coming from the Tubular base to the solenoid valve housing. 2. Fit the water supply inlets (hot and cold water inlet) to the adapter at each of the solenoid valve housings.
Page 9
FAUCE T I NSTAL L AT I ON Step 3 – Connecting the power source 1.a. For Tubular 1000 B: Connect the cable coming from the electronic unit at the Tubular base leading to the power the Tubular base leading to the power source to the battery box.
Page 10
FAUCE T I NSTAL L AT I ON Installation instructions for & & & TUBULAR 1000 B BOX TUBULAR 1000 E BOX Step 1 – Installing the faucet 1. Shut off the water supply 2. Cut an adequate opening in the wall for the dimensions of the Tubular box, the cables sleeve, the rigid pipes and the Tubular base (at the place...
Page 11
FAUCE T I NSTAL L AT I ON Important: The Tubular base should be installed so that the outside surface of the finished wall falls between the minimum and maximum lines marked at protective plastic cover. 5. Assemble the rigid pipes from the nipple at the box to the inlets at the Tubular base.
Page 12
FAUC ET IN STA LL AT IO N 14. Fix the Tubular spout by inserting the nipples from the Tubular base. Make sure that this area is clean before proceeding. 15. Secure the screw with the Allen key. Make sure that the aerator at the Tubular spout faces the washbasin.
Page 13
FAUCE T I NSTAL L AT I ON 3. After you have connected the power source (Battery or Transformer) wait about 10 seconds in order to allow the system to set the ideal sensor range. Then the product will be ready for use. 4.
SETTINGS ADJUSTMENT Adjusting the sensor range with the remote control Tubular was supplied with Stern’s new Self Adjusting Sensor. The ideal sensor range for the specific location will be set automatically. Only if necessary, use the remote control to adjust the sensor range as follows: Shut off the water supply.
BATTERY REPLACEMENT Battery models only When the battery weakens, the red indicator light will blink at a constant rate when the user’s hands are within the sensor range. The battery must be replaced within two weeks. Always use batteries from a reputable source. Poor quality batteries may affect the performance of the product.
Page 16
M A I N T E NA NC E Filter cleaning instructions This tap is provided with a stainless steel filters preventing foreign particles to enter the lines. If the water flow has decreased, this may be because the filter is clogged.
S PA R E PAR TS LI ST Self adjusting sensor kit Cat.No. 07220056 Solenoid valve kit Cat.No. 07500100 Solenoid housing kit Cat.No. 07231001 Transformer Cat.No. 06522025 IP67 Battery box Cat.No. 06522020 Diaphragm Cat.No. 04500001 Optional accessories Remote control Cat.No. 07100002 Battery box for 1 x 9V battery Cat.No.
T RO U B LE S HO OT IN G PROBLEM PROBLEM PROBLEM PROBLEM INDICATOR INDICATOR INDICATOR INDICATOR CAUSE CAUSE CAUSE CAUSE SOLUTION SOLUTION SOLUTION SOLUTION No water 1.Sensor flashes Low battery. Replace battery. coming out continuously when user’s hands are within of the tap: the sensor’s range.
This product is covered by a limited warranty for two years from date of purchase. During this period, STERN undertakes, at its option, to repair or replace any faults caused by defective materials or manufacturer defaults that may arise (see Stern Warranty).
Page 20
15 Gan Rave Blvd., 81222 Gan Rave, Yavne, Israel Tel: 972-8-9326000, Fax: 972-8-9326025, export@sternfaucets.com www.sternfaucets.com...