DO200 Parking Occupation Sensor_LoRaWAN_V2.1
DO200 Parking Occupation Sensor
Configuration Manual
-----LoRaWAN Version
V2.1
Date:2019-09-10
Beijing Dingtek Technology Corp., Ltd.
Tel:86-10-64718863,64753700
http://www.dingtek.com
E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DO200 and is the answer not in the manual?

Questions and answers

Summary of Contents for CNDINGTEK DO200

  • Page 1 DO200 Parking Occupation Sensor_LoRaWAN_V2.1 DO200 Parking Occupation Sensor Configuration Manual -----LoRaWAN Version V2.1 Date:2019-09-10 Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863,64753700 http://www.dingtek.com E-mail: service@dingtek.com Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 1...
  • Page 2 DO200 Parking Occupation Sensor_LoRaWAN_V2.1 Changed V2.1 Change the picture of the hardware; add interface of capacity; V2.0 Change the hardware; V1.0 Initial version; Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863,64753700 http://www.dingtek.com E-mail: service@dingtek.com Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022...
  • Page 3: Table Of Contents

    DO200 Parking Occupation Sensor_LoRaWAN_V2.1 1 Overview..............................4 Index 2 Device Function DO200_LoRaWAN Parking Occupation Sensor's........... 4 3 The Main LoRaWAN Band Introduction....................4 4 How to restart sensor through magnet?..................... 5 5 Device interface definition........................6 6 Modify device parameters(Upload time...)..................6 6.1 Required tools..........................
  • Page 4: Overview

    DO200 Parking Occupation Sensor_LoRaWAN_V2.1 1 Overview These documents are helpful to understand the DO200 Parking Occupation Sensor’s following: ▪Function of Device ▪Hardware Interface(debug/configure interface and battery interface ) ▪Modify equipment parameters ( upload interval ..) ▪Modify LoRAWAN parameters ( deveui,appeui,band..) ▪Protocol and API...
  • Page 5: How To Restart Sensor Through Magnet

    DO200 Parking Occupation Sensor_LoRaWAN_V2.1 The default uplink CN470 Band 470.3,470.5,470.7,470.9, 500.3,500.5,500.7, RXWIN1 505.3 RXWIN2 frequency (470-510MHz) 471.1,471.3,471.5,471.7, 500.9501.1,501.3,5 01.5,501.7 EU868 868.1,868.3,868.5 868.1,868.3,868.5 869.525 (863-870MHz) US915 902.3,902.5,902.7,902.9, 923.3,923.9,924.5, 923.3 (902-928MHz) 903.1,903.3,903.5,903.7 925.1 925.7,926.3,926.9, 927.5 AU915 915.2,915.4,915.6,915.8 923.3,923.9,924.5, 923.3 (915-928MHz) 916.0,916.2,916.4,916.6 925.1 925.7,926.3,926.9,...
  • Page 6: Device Interface Definition

    DO200 Parking Occupation Sensor_LoRaWAN_V2.1 5 Device interface definition The detailed of power interface , device parameter configuration interface are given here, as shown in figure 5.1. Connect the capacity(blu e,2pin) here This power socket is This interface is used used to connect the to configure device battery.
  • Page 7: Required Tools

    DO200 Parking Occupation Sensor_LoRaWAN_V2.1 This section describes how to modify the parameters of the device through the serial port, such as upload time interval, and so on. TTL and its cable; TTL and cable for the goods accessories Please check these 6.1 Required tools...
  • Page 8: Configure Device Parameters (Upload Time, Etc.)

    DO200 Parking Occupation Sensor_LoRaWAN_V2.1 Figure6.3 TTL and device connection as shown in figure 6.4: Sensor TTL Tools Figure6.4 Figure 6.5 6.3 Configure device parameters (upload time, etc.) Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863,64753700 http://www.dingtek.com E-mail: service@dingtek.com Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022...
  • Page 9 Open the serial port software. The default serial port information is shown in Figure 1 serial port software parameter setting 6.6. The parameters required for the DO200 serial port are shown in Figure 6.7; Port number ( you can select port Number from device manager of your system) Set the baud rate: 115200...
  • Page 10 DO200 Parking Occupation Sensor_LoRaWAN_V2.1 Figure6.7 parameters setting Connect the capacity and battery to the (2pin)connector location on the 2 Connect the device's power(battery) motherboard as shown in Figure 6.8: Figure6.8 Connect the battery When power it on, you can see some information output from the serial port. At this 3 Send command point, the device starts working and can send commands.
  • Page 11: Modify Lorawan Parameters(Deveui,Appeui,Band

    Open the serial port software. The default serial port information is shown in Figure 1 serial port software parameter setting 7.1. The parameters required for the DO200 serial port are shown in Figure 7.2; Port number ( you can select port Number from device manager of your system) Beijing Dingtek Technology Corp., Ltd.
  • Page 12 DO200 Parking Occupation Sensor_LoRaWAN_V2.1 Set the baud rate: 115200 Parity bit: NONE Data bits: 8 Stop bit: 1 Figure7.1 Interface by default Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863,64753700 http://www.dingtek.com E-mail: service@dingtek.com Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022...
  • Page 13 DO200 Parking Occupation Sensor_LoRaWAN_V2.1 Figure7.2 parameters setting When power it on, you can see some information output from the serial port. At this 2 Power the device on point, the device starts working and as following below; Periodically send in 50ms, as shown in Figure 7.4;...
  • Page 14 DO200 Parking Occupation Sensor_LoRaWAN_V2.1 Figure 7.5 Information after restarting the device Figure7.6 Information after sending instruction 1 Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863,64753700 http://www.dingtek.com E-mail: service@dingtek.com Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 14...
  • Page 15 DO200 Parking Occupation Sensor_LoRaWAN_V2.1 Figure 7.7 Switching baud rate Figure7.8 Switching baud rate Command:AT+ID Example 1: Reading LoRaWAN Parameters Enter the command in the serial port software, click Enter, and click Send, as shown in Figure 7.9. Reply: +ID: DevAddr, 00:00:37:1E...
  • Page 16: Protocol And Api Interface

    The communication protocol(API Interface) is confidential is only open for customer who has purchase the device and sign the NDA(non-disclosure agreement) file with CNDingtek and his own Company. Please contact our sales team service@dingtek.com if you want to integrate the protocol/API with your own system.