International Shock Sensor Installation
Instructions
Product summary
The International Shock Sensor (RF620I4, RF620I4B,
RF620I4-N, and RF620I4B-N ) has the following main
functions:
To detect the vibrations made by an intruder trying to
break a window or door.
To detect a window or door opening.
To detect tamper situations, such as an intruder removing
the sensor cover.
Figure 1: Shock sensor
Vibrations cause a momentary open circuit in the shock
element of the sensor. The circuit closes again when the
vibration stops. The sensor microcontroller "sees" the
open/close action as a pulse, causing the sensor to transmit an
alarm signal. The sensor has two different detection modes:
Gross Attack - detect a violent blow sufficient in length to
trip sensor.
Pulse Count - detect a sufficient number of less violent
blows (rapping or tapping).
The sensor includes an internal magnetic reed switch that must
be disabled if it is not used.
A cover tamper provides additional security if an intruder tries
to disable or damage the sensor.
© 2019 UTC Fire & Security Americas Corporation, Inc.
Figure 2: Shock sensor main components
Installation guidelines
Figure 3: Mounting options for door/window styles
1 / 4
P/N 466-1911 • REV F • ISS 11MAR19

Advertisement

loading
Need help?

Need help?

Do you have a question about the interlogix RF620I4 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for United Technologies interlogix RF620I4

  • Page 1 International Shock Sensor Installation Instructions Figure 2: Shock sensor main components Product summary The International Shock Sensor (RF620I4, RF620I4B, RF620I4-N, and RF620I4B-N ) has the following main functions: • To detect the vibrations made by an intruder trying to break a window or door. •...
  • Page 2 • Figure 5: Mounting on a horizontal surface Learn the sensor before adjusting the shock sensitivity. The sensor is shipped with the reed switch enabled and open, and this is how it must be learned. • Before permanently mounting the sensor, test it at the intended location to make sure that the panel can receive sensor signal transmissions.
  • Page 3 Figure 7: Sensor base mounting holes and magnet alignment Table 1: Gross attack sensitivity settings DIP Switch 3 DIP Switch 4 Sensitivity 1 (maximum sensitivity) 4 (minimum sensitivity) Pulse count adjustment Set the sensor to the desired Pulse Count (see Table 2 below).
  • Page 4 Reed switch setting Notices After adjusting the Shock Sensor’s sensitivity, set DIP switch 5 Approved for use in the following countries: to the appropriate setting, ON for enabled and OFF for Austria France Ireland disabled. Belgium Germany Italy Denmark Greece Netherlands RF testing Finland...

This manual is also suitable for:

Interlogix rf620i4bInterlogix rf620i4-nInterlogix rf620i4b-n