Download Print this page

Dimplex B075E Installation And Operating Instructions page 2

Oil filled panel

Advertisement

This guide is for quick reference only
To view the full manual, please scan this QR code using your
Smartphone or visit the product page at www.dimplex.co.uk
Energy Related Product Directive
This product complies with Lot20 of the Energy Efficiency Directive (2015/1188)
Type of heat output/ room temperature control
With electronic room temperature control
Electronic room temperature control plus week timer
With open window detection
With adaptive start control
Model Identifier(s):
Nominal heat
Pnom
output
Height (mm)
Width (mm)
Depth (mm)
Minimum heat
Pmin
output (indicative)
Maximum continuous
Pmax,c
heat output
Auxiliary electricity Consumption
At nominal heat output
elmax
At minimum heat output
elmin
In standby mode
elSB
With open window detection
With adaptive start control
General Information
Please read the instructions closely before first using the product.
This heater may be used wall-mounted or freestanding. The necessary wall mounting brackets
are provided with the product as a standard. The feet screws can be bought separately as an
accessory.
It should only be operated when in the upright position as shown - see Fig.1a and Fig.1b. All
models are IP20 rated. Before connecting the heater check that the supply voltage is the same
as that stated on the heater.
Wall Mounting
IMPORTANT - The radiator must only be mounted using the kit supplied
WARNING - This product is heavy and care should be taken in installation
Select a suitable position on a wall, near to a mains power outlet. The radiator
should not be mounted closer than 75mm from the floor - see Fig. 2 (to enable
cleaning), or adjacent side walls. Ensure at least 305mm clear space between
the radiator and any overhanging shelf. It should not be mounted closer than 1
metre from the ceiling.
Yes
Yes
Yes
Yes
B075E
C100E
D150E
0.75 kW
1 kW
1.25 kW
659
659
659
570
840
1105
50
50
50
0.75 kW
1.00 kW
1.25 kW
0.75 kW
1.00 kW
1.25 kW
0.00
0.00
0.00
0.00
0.00
0.00
<0.0005
<0.0005
<0.0005
Yes
Yes
STEP 1: Check that you have all the necessary components:
(a) 2 x Bottom wall brackets
(b) 2 x Top wall brackets
(c) 2 x Radiator securing brackets
(d) 2 x Self-tapping screws.
STEP 2: Using a straight edge, draw a horizontal line (see 'Y' in Fig. 2) for the bottom brackets
at the required mounting height from the floor.
NOTE - The bottom of the radiator must not be less than 75mm from the floor.
To achieve this the top edge of the bottom brackets must be at least 160mm
from the floor - see Fig 2. On this line, mark off the fixing centres according to
model - see `C' in the table in Fig. 2 and Fig.3
Place the bottom brackets centrally over these centres with the top row of holes
on the line, and mark the fixing hole positions – see Fig. 3.
STEP 3: Drill the holes and fit wall plugs. Screw the bottom brackets in position
– see Fig. 3.
E200E
STEP 4: Measure dimension D in Fig. 2 according to model, from the top of the bottom brackets
1.5 kW
and draw a horizontal line. Mark off the fixing centres for the top brackets in line with
659
the bottom brackets. Place each top bracket on the line and mark the fixing holes – see
1373
Fig. 4. Drill and plug the wall and fix the top brackets in place.
50
STEP 5: Place the radiator on the bottom brackets, then fit each securing bracket to the top of
1.5 kW
the radiator and secure it with the self-tapping screw provided – see Fig. 5.
1.5 kW
Check that the radiator is securely fixed to the wall.
0.00
0.00
<0.0005
'Y'
'C'
75
75
mm
mm
(min)
(min)
Fig. 4
Fig. 2
Fig. 3
Fig. 5
93
mm
67
mm