Advertisement

Quick Links

X2 marine 15 - B2 HB
English
MAEN228, 2021-11

Advertisement

Table of Contents
loading

Summary of Contents for Beijer Electronics X2 marine 15 - B2 HB

  • Page 1 X2 marine 15 - B2 HB English MAEN228, 2021-11...
  • Page 2 The information in this document is subject to change without notice and is provided as available at the time of printing. Beijer Electronics AB, including all its group companies, reserves the right to change any information without updating this publication. Beijer Electronics AB, including all its group companies, assumes no responsibility for any errors that may appear in this document.
  • Page 3: Table Of Contents

    Digital Outputs ..........20 X2 marine 15 - B2 HB Outline ......... 21 7 Additional Installation Tips ..........
  • Page 4: Safety Precautions

    Toxic and hazardous materials or elements 零件描述 有毒和有害的材料或元素 Cr6+ PBDE PCB and electronic components PCB 和电子元件 O: Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is below the relevant threshold of the GB/T 26572-2011 Beijer Electronics, MAEN228...
  • Page 5: Disposal Requirements Under Weee Regulations

    À L'HEURE ACTUELLE, AUCUNE UNITÉ DE CE TYPE N'A ÉTÉ TESTÉE OU AUTORISÉE Warning: Explosion hazard! Substitution of components may inpair suitability for Class I, Division 2. RISQUE D’EXPLOSION! LA SUBSTITUTION DE COMPOSANTS PEUT NUIRE Á LA CONFORMITÉ DE CLASSE I, DIVISION 2. Beijer Electronics, MAEN228...
  • Page 6: During Installation

    Separate the high voltage, signal, and supply cables. • Make sure that the voltage and polarity of the power source is correct before connecting the operator panel to the power outlet. • Peripheral equipment must be appropriate for the application and location. Beijer Electronics, MAEN228...
  • Page 7: During Use

    • Replacing the battery incorrectly may result in explosion. Only use batteries recommended by the supplier. During the warranty period, the battery needs to be replaced by an authorized Beijer Electronics service center. 1.7.1 Cleaning the Display We recommend using a dry, clean cloth to wipe off dust regularly. Use alcohol or ammonia-based cleaning agent for cleaning only when necessary.
  • Page 8: Dismantling And Scrapping

    The layer structure of the touch screen contains air. In rare cases, the appearance of bubbles can arise. This is purely cosmetic and does not affect the functionality of the operator panel. The appearance can occur under certain environmental conditions such as temperature, humidity, and atmospheric pressure. Beijer Electronics, MAEN228...
  • Page 9: Naming Convention

    X2 extreme 7 SL HP* • X2 extreme 12 SL HP SC* • X2 extreme 7 CO* • X2 extreme 12 SL HP RO Note: Not all combinations are available. Note: * indicates variants including IECEx\ATEX and C1D2 accreditation. Beijer Electronics, MAEN228...
  • Page 10: Installation

    2. To cut a correct opening for the operator panel, use the cut out dimensions in the outline drawing. A separate cut out drawing is available for download from the Beijer Electronics web site. For more information, see sections Operator Panel Drawings Technical Data.
  • Page 11 Tighten the screws to 0.7 Nm ± 0.2 Nm. 6. In cases where the front panel seal (IP54 or greater, NEMA-4X) is critical, use a torque wrench to ensure all screws are torqued within the specification above. Beijer Electronics, MAEN228...
  • Page 12: Connections To The Controller

    3.2.1 Connections to the Controller For information about the cables to be used when connecting the operator panel to the controller, please refer to the help file for the driver in question. Beijer Electronics, MAEN228...
  • Page 13: Other Connections And Peripherals

    Installation 3.2.2 Other Connections and Peripherals Cables, peripheral equipment and accessories must be suitable for the application and its environment. For further details or recommendations, please refer to the supplier. Beijer Electronics, MAEN228...
  • Page 14: Technical Data

    Technical Data Technical Data Parameter X2 marine 15 - B2 HB Front panel, W × H × D 410 × 286 × 8 mm Cut out dimensions, 394 × 270 mm W × H Mounting depth 53 mm (153 mm including clearance) Standalone mounting VESA 75 ×...
  • Page 15: Compass Safe Distance

    Technical Data Parameter X2 marine 15 - B2 HB Battery BR 2032 lithium battery replaceable Power consumption 31.2 W at rated voltage Fuse Internal DC fuse, 4 AT, 5 × 20 mm Power supply +24 V DC (18–32 V DC) CE: The power supply must conform with the requirements according to EN/IEC 60950 and EN/IEC 61558-2-4.
  • Page 16: Chemical Resistance

    Phenol Xylene Ammonia, conc. Sodium hydroxide 5% 97 octane unleaded petrol Ethyl acetate Sodium hydroxide 30% 98 octane leaded petrol Touch Screen and Overlay Material 5.2.1 Protective Film Autoflex EBA 180L covers the overlay surrounding the screen. Beijer Electronics, MAEN228...
  • Page 17 The Autoflex protective film is not resistant to high pressure steam at over 100 °C or the following chemicals: Concentrated mineral acids Benzyl alcohol Concentrated caustic solution Methylene chloride Beijer Electronics, MAEN228...
  • Page 18: Touch Screen Surface

    5.2.3 Touch Screen Protector For harsh environments and exposure to outdoor conditions, it is recommended to use a protective film to guard the touch screen from damage. This optional part can be ordered from Beijer Electronics. Beijer Electronics, MAEN228...
  • Page 19: Operator Panel Drawings

    RS-422 Tx- CAN 1-L RS-485 Tx-/Rx- RS-232 RTS RS-232 CTS RS-485 RS-422 Rx- CAN 2-L Tx-/Rx- The connector supports up to three independent communication channels and can be configured for RS-232 and RS-422 or 2xRS-485 or 2x CAN. Beijer Electronics, MAEN228...
  • Page 20: Digital Outputs

    32.0 V (DC) / 22 V (AC) Maximum load current 0.5 A (DC) / 0.5 A (AC) Isolation Channel to Channel 1000 V (DC) / 550 V (AC) Channel to System 1000 V (DC) / 550 V (AC) Beijer Electronics, MAEN228...
  • Page 21: X2 Marine 15 - B2 Hb Outline

    Operator Panel Drawings X2 marine 15 - B2 HB Outline maxi mum mater i al thi c kness 8 mm "Di gi tal I O" not i nc l uded wi th X2 pr o X2 mar i ne 15-B 2 and X2 mar i ne 15-B 2 H B Note: A Step CAD file is available on the web site...
  • Page 22: Additional Installation Tips

    3 turns around the ferrite core provide 9 times the suppression of 1 turn. Connect a wire or grounding braid, that is sized correctly according to local electrical codes, between the chassis of the operator panel and the closest grounding point. Beijer Electronics, MAEN228...
  • Page 23: Ethernet Connection In The Operator Panel

    1. Check whether the other Ethernet unit has its shield directly grounded or grounded via a capacitor. Note: In many cases, connecting the shielded Ethernet cabling to the chassis at both ends is inappropriate. Hum or grounding loops can occur. Unshielded cabling may even result in fewer communication errors. Beijer Electronics, MAEN228...
  • Page 24: To Achieve Better Emc Protection

    This connects the HF transients to ground. To Achieve Better EMC Protection • Initially, use the original cabling from Beijer Electronics primarily. • Place the 24 V DC and communications cabling in one cable trunk/cable duct and 230/380 V AC in another. If the cables need to be crossed, cross them at 90°...
  • Page 25: Ambient Temperature

    Install the fan so that it sits in a cooler area and blows cold air against the operator panel. If the fan is mounted at the top and sucks warm air upwards, the ambient temperature of the fan becomes higher, resulting in a shorter lifespan. Beijer Electronics, MAEN228...
  • Page 26 This is assuming that all supplied power is transformed to heat. Note: Please ensure that the temperature will not exceed the maximum ambient operating temperature in the enclosure. This can be influenced by other heat generating devices. Beijer Electronics, MAEN228...
  • Page 27: Safety

    Transients on the 24 V feed are connected to the ground. • No risk that the 24 V feed is at a high level in relationship to the ground. This is not unusual since there is high static electricity. Beijer Electronics, MAEN228...
  • Page 28: Galvanic Isolation

    If a number of units are connected that have a 0 V and a ground connection, and these are connected to various grounding points, there is a substantial risk of problems. Grounding currents go through communication cables, the rear plate of the controller, internally in the operator panel, and can cause errors. Beijer Electronics, MAEN228...
  • Page 29 24 V feed, disturbances and grounding currents from the 0 V on the 24 V side disrupt the communication. Using this type of unit solves one problem but creates a larger problem! A substandard installation may work now, but problems may arise when other devices are connected. Beijer Electronics, MAEN228...
  • Page 30: Cable And Bus Termination Rs-485

    CAN nodes with 118 Ohm... 130 Ohm resistors. The recommended resistor value is 120 Ohm/1%/0.25W on each end. • Place the termination resistor near the CAN bus connector (as close as possible). • This product has no integrated termination resistors. They must be added externally. Beijer Electronics, MAEN228...
  • Page 31: Restrictions And Recommendations

    Use the screensaver functionality (see SW manual). • Changing constantly between static and dynamic images. • Avoid excessive brightness differences between foreground and background elements. • Use colors with similar brightness. • Use complementary colors in follow-up images. Beijer Electronics, MAEN228...