reached.
• Adjust the height of the plastic base to obtain a small gap
between the gate/foot assembly and the top side of the tongue
of the sample board. A gap of 1/32" should be adequate for
most situations.
• Tighten both screws (A).
Step 2: adjusting the resting block for the width of the tongue:
• Using the Allen wrench, loosen by about 1/2 turn n do not
remove the two screws (C).
• With the short piece of flooring still against the gate/foot
assembly, adjust the gap between the resting block and the
tongue with screw (D). A small gap of 1/32" should be
adequate for most situations.
• Tighten both screws (C).
• Ensure that screw (D) is slightly tighten. Do not apply force on
screw (D) once screws (C) are tighten.
After completing the adjustment procedure, proceed with the
installation of few boards. Carefully check for the proper positioning
of the fastener onto the board. Check again after few more rows to
insure that all parts are secured in place. Tool may lose adjustment
over time if this procedure is not strictly followed.
B
EFORE STARTING AN INSTALLATION
BOARDS TO ASCERTAIN THAT YOU ARE USING THE RIGHT
TOOL AND FASTENER

PREVENTIVE MAINTENANCE

This tool requires minimal lubrication. Use only detergent-
free oil such as Primatech P-090. Few drops of oil weekly
in the air inlet is sufficient. Other types of lubricant may
degrade the seals.
Check periodically to make sure that all screws are tight. Pay
particular attention to the two screws holding the feeder channel as
well as the screws and nuts on the feeder channel assembly who
might loosen up over time. The use of an medium strength
adhesive sealant is recommended.
MAINTENANCE & REPAIR
Most adjustments to the tool can be made with the 3/16" Allen
wrench supplied with the tool.
Disassembly of the tool must be done in a clean environment.
Some parts can be easily damaged if disassembled with improper
tools or by inadequate methods. Maintenance should only be
performed by trained personnel. Use only genuine P
replacement parts.
T
O PREVENT INJURY
SUPPLY HOSE WHEN SERVICING OR DISASSEMBLING THE
.
TOOL
When servicing the tool, do not twist or force any parts. Damage
may result from such abuse. If parts do not come loose easily,
contact your P
distributor for more information.
RIMATECH
When opening the tool for maintenance, always clean all
components of dirt, grit, or particles. Inspect the tool carefully for
broken parts or excessive wear, and replace if necessary. When
ordering parts, be sure to specify the right part number, and also
the tool serial number.
,
FASTEN DOWN FEW
.
, ALWAYS
DISCONNECT THE AIR
NEVER apply threadlocker
or adhesive onto cylinder
or head threads.