OPERATION (HCE220 ONLY)
NOTE: Never leave an operating heater unattended.
All Purpose Heater Operation
Plug the heater into a polarized 120V outlet.
DO NOT FORCE THE POLARIZED PLUG INTO THE OUTLET;
it will only fit one way.
Press the Power Icon ( ) to turn the heater on. The red Power Light
will come on. This heater is equipped with two (2) settings: Low ( )
and High ( ). The Low ( ) heat setting uses 900 Watts of power
and the High ( ) uses 1500 Watts of power. You can select the
proper setting to accommodate your comfort level with the Setting
Button (
). Because the Low ( ) heat setting does not require as
much electricity to operate, it is more energy efficient.
The Adjustable Thermostat button ( ) is equipped 4 pre-set Heat
Levels. To set Thermostat to one of these levels, press the Thermostat
button ( ) until the desired temperature is illuminated. The heater
will operate at the High setting until the room reaches the desired
temperature. The heater will turn off when the room reaches desired
temperature and until the room temperature goes below selected
temperature and then it will turn back on. The heating element will
turn off, but the fan will continue to operate to cool the internal before
shutting off completely.
The Timer button ( ) is equipped with three (3) settings: two hours
(2h), four hours (4h) and eight hours (8h). The timer option will
illuminate once selected. The timer is not on if none of those three
(3) timer settings are illuminated.
To turn the unit off, push the Power Button Icon ( ). The heating
element will turn off, but the fan will continue to operate to cool the
internal before shutting off completely.
SAFETY FEATURES (HCE210 & HCE220 SERIES)
This heater is equipped with several devices and features for added protection:
Two high temperature safety sensors prevent overheating. If activated, unplug the device and wait at least
10 minutes or allow the unit to cool completely. Make sure the operating conditions are safe and then plug
the heater back in and follow the OPERATION instructions.
Made with high temperature plastic and a cool to touch housing and handle.
HCE220 Series Only: An Auto Shut Off feature will turn the heater off after 8 hours of use. When the unit is
powered on it automatically will default to 8h Timer Selection for this added feature.
Unit is equipped with a Tip Over switch, which will automatically shut off unit if the device is tipped over.