Page 1
Instructions and Proper Use UM 34 Prevost H-Series Vehicle Entry/Push to Start System TriMark Corporation 500 Bailey Avenue New Hampton, Iowa 50659 08/22-1 TriMark TriMark Corporation United States www.trimarkcorp.com...
Introduction This manual provides the necessary information for the proper use of TriMark’s e-ASK System including module and keypad in the Prevost system. e-ASK module or controller 32-Bit CAN Keypad or Keypad Push to Start This vehicle is equipped with an advanced push to start ignition system. The start/ignition sequence is accomplished via CAN messaging between the Prevost Mux Module and the e- ASK module.
• If the entrance door is closed (J1P11=inactive or float) o Activates Wake Out (J1P10=GND for 1 second) o Attempts arming the alarm (see Alarm) o Locks entrance door by pulsing door Lock Relay (J1P5 +, J1P6 -) for ½ second o Sends CAN message to MUX for 2 seconds to lock the luggage doors Unlock Entry/Unlatch All the following methods will unlock the entry door:...
Teaching Transmitter FOBs The keypad is the only method of syncing fobs. The following sequence puts the e-ASK module into a “Fob Learn” mode. 1. Press 5/6 button on the keypad for 5 seconds, listen for double beep a. Keypad backlight continuously flashes on/off 2.
Locking doors with keypad Press and hold the (9/0) button for 1-2 seconds. An access code is not needed to lock the doors Keypad Secure Operations Entering a valid 4-digit access code enables secure operations. After entering an access code, the keypad is enabled for 5 seconds and a fifth button press and release initiates a secure operation.
To delete access codes 8. After the 3/4 key is pressed (step 3 above), if there are no access codes stored in memory, the keypad beeps for 2 seconds and returns to step 3 above. If there are stored codes, the keypad beeps twice. 9.
• Entrance door is opened, door ajar input J1P11 is active (grounded) • Entrance door is unlocked, Entrance door key switch J1P8 is active (grounded) The Prevost Mux system is configured at the time of delivery with the following options related to the Alarm: (Prevost Field service personnel can re-configure).
Panic is disabled by pressing any fob button (other than the Panic button) or unlocking the entrance door via the keypad. Replacing the 32-Bit CAN Keypad For improved security/theft prevention, the keypads and e-ASK controllers are paired at the factory to prevent swap-out violations. If the keypad is changed, the keypad will play a 2 second error beep.
CAN Address Conflict EEPROM Read/Write Error Keypad Status LED’s and Backlighting The Keypad back lighting is typically off. When a button is pressed, the backlight illuminates momentarily. After button presses stop, the backlight is low for 30 seconds. After 30 seconds of no keypad activity the keypad back lights turn off again.
One particular e-FOB function does Check wire connection of affected function at RF module, not work wiring harness, and e-ASK module. 32-Bit CAN Keypad Hints Verify power and ground connections to the Keypad. No response with button press Verify that keypad cable is connected. (rest of system will function).
émetteur Note: No part of this publication may be copied, modified, revised, reproduced, distributed, reused, transmitted to a third party, or translated in any language without the prior written permission of TriMark Corporation.