5.2 - Product Installation & Set-up (continued)
2. Installation of the #SB-SM1 4-Arm Manway Mount:
Choose a location where installation will provide suitable proximity to the work area yet minimize obstructions during
use and in the event a rescue is necessary.
• W henutilizedasaFallArrestTowerAnchorage: Install the mount so that the tower to be utilized will clear
all obstructions yet provide full access to all required work areas within the towers's safe working radius.
**Once a location is chosen, Ensure that the manway to which the mount will be attached is
capable of withstanding all of the forces imparted to it by the proof-loaded system (Refer to
Section 5.1 of this manual).
a. Loosen any mounting hardware to which the 4 arms of the manway mount will be bolted to.
b. Position the mount so that each pivoting arm is angled to their respective corners (Refer to Fig. #5.2c & #5.2d).
c. Secure the mount by sliding the slider blocks within the arms to the mounting holes on the manway (Refer to Fig.
#5.2e).
d. Ensure that the mounting base of the #SB-SM1 is as close to the center of the manway as possible.
e. Tighten all hardware to standard dry torques according to the size of the mounting hardware.
! WARNING ! - Mounting hardware must be greater or equal to 1/2" in diameter!
f. Check to see and ensure that the arms of the manway mount sit flush to the manway cover and all hardware is
tightened.
Figure #5.2b: #SB-SM1
Pre - Installation
Mounting
Block
Figure #5.2e: #SB-SM1
Slider block
Page 14
Figure #5.2c: #SB-SM1
! WARNING ! - Each corner of the base plate of the Model #SB-
SM1 Fall Arrest Tower base must be located above its respective
"arm" when the system is installed (Refer to Figure #5.2d). The
system is not approved for usage when any of the "arms" lie outside
of the angular boundaries dictated by the plate's corners.
Figure #5.2e: #SB-SM1
Completely Installed
!WARNING! - The user must ensure that
the #SB-SM1 is properly installed & securely
mounted on the selected manway before
attaching any lifeline or additional fall arrest
system components.
#500964-001 - Product Manual: Model #SB-SM1 Fall Arrest Tower Base - Revision 01 - Date: 03-04-2010
Installation
! WARNING ! - The user must ensure
that the manway to which the #SB-SM1 is
attached is capable of withstanding all of
the loads imparted to it by the device when
proof-loaded. There is a limitless variety
of manway configurations and address-
ing each potential scenario is beyond the
scope of this manual. A "qualified person"
must approve each attachment point.
Figure #5.2d: #SB-SM1
Base Arms