Troubleshooting Guide

Observed Problem
Switch timer does not switch ON/OFF but
Switch timer is not set in AUTO, RANDom, or
display looks normal.
MANual mode.
Switch timer won't enter AUTO or
The time of day or timer settings have not
RANDom mode when you press MODE.
been set.
Programmed schedule(s) are incorrect.
Switch timer is in RANDom mode, which var-
ies switching times up to ±20 minutes (to give
your home a "lived-in" look).
The Astronomic and Specific switching times
are in conflict. For example, you've set ON to
Switch timer switches at incorrect times
DUSK and OFF at 8 pm, and due to seasonal
or skips some of the programmed times.
changes, DUSK has advanced to 8:30 pm.
NOTE: Your switch timer automatically skips
any conflicting ON event as summer ap-
proaches to prevent unwanted operation of
lights or other controlled devices. See "What
to Do" if you want to identify and remove
conflicting settings.
The lights or controlled devices don't
Switch timer does not "catch up" automati-
match the programmed ON/OFF status
cally to the programmed load state. The status
immediately after setting the time or
of the switch timer will remain as is until it
programming a schedule.
comes to the next programmed ON/OFF time.
Load only operates when the remote
(3-way) switch is in one position, or the
The remote switch is wired incorrectly.
switch timer ignores the remote switch.
There is an excessive length of wire (more
than 100 feet), or there is buried wire to the
The switch timer ignores a 3-way remote
switch.
switch even though it is wired correctly.
The remote switch is not functioning properly
or worn out.
The remote switch or switch timer is wired
wrong.
There is an excessive length of wire
The load turns off immediately after being
(greater than 100 feet)
turned on.
There is buried wire to the remote switch.
The switch timer is not functioning properly.
Battery is not seated in the tray.
The battery tray is difficult to replace.
The tray is misaligned.
The contact tabs of the tray are bent.
The switch timer operation is sluggish or
Though the "BATT" message is not being
not switching ON/OFF at all.
displayed, the battery is getting weak.
Timer shows ON but the light or other
The light or controlled device itself may be
controlled device is OFF.
switched OFF.
LIMITED FIVE-YEAR WARRANTY
If within one (5) years from the date of purchase, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its sole option, free of charge. This war-
ranty is extended to the original household purchaser only and is not transferable. This warranty does not apply to: (a) damage to units caused by accident, dropping or abuse in handling, acts of God or
any negligent use; (b) units which have been subject to unauthorized repair, opened, taken apart or otherwise modified; (c) units not used in accordance with instructions; (d) damages exceeding the cost
of the product; (e) sealed lamps and/or lamp bulbs, LED's and batteries; (f) the finish on any portion of the product, such as surface and/or weathering, as this is considered normal wear and tear; (g) transit
damage, initial installation costs, removal costs, or reinstallation costs.
INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL
DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING THE
WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE OF
THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE. SOME STATES DO NOT ALLOW LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATION MAY NOT APPLY TO
YOU.
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing the product, along with proof of purchase, postage prepaid to the autho-
rized service center listed below. This warranty is made by: Intermatic Incorporated/After Sales Service/7777 Winn Rd., Spring Grove, Illinois 60081-9698/815-675-7000 http://www.intermatic.com Please be
sure to wrap the product securely to avoid shipping damage.
SPRING GROVE, ILLINOIS 60081-9698
Possible Cause
What to Do
Press MODE to select the operational mode you
want to use.
Make sure the time of day and at least one sched-
uled activity have been set.
Press ON/OFF to review the settings and revise
them as necessary. See instructions at the left.
If you don't want to keep the switch timer in
RANDom mode, press MODE to change to AUTO
mode.
1.
Complete the steps for setting the Time and
Date, then temporarily change the date to June
21st.
2.
Review the DAWN and DUSK settings by push-
ing the ON/OFF button.
3.
Make sure the specific ON or OFF time settings
won't interfere with these DAWN and DUSK
times. Make changes as necessary.
4.
When finished, change the Date setting back to
today's date.
After entering your schedules or the time, then
returning to the AUTO mode, push the ON/OFF but-
ton to change the load state if necessary.
Recheck the wiring, especially for the jumper,
according to "If a 3-way Switch Timer" and "If a
Multiple Switch Timer Setup."
Eliminate the condition: either replace the buried
cable, do without the remote switch, or contact
Intermatic Customer Service for more options.
Replace the remote switch.
If the problem persists with the switch timer's red
wire disconnected or with a remote switch tempo-
rarily connected right at the switch timer, replace
the non-functioning switch timer. Otherwise, try
the above suggestions.
Seat the battery in the tray, then reinstall.
To test the battery, press the
Replace the battery.
ON/OFF button. The timer should "click."
Make sure the light or controlled device is
switched ON and plugged in.
INTERMATIC INCORPORATED
MODEL EI600 Series
Installation and User Instructions
Ratings
Resistive (heater) 20 Amp, 120-277 VAC
Tungsten (incandescent) 15 Amp @ 120 VAC, 6 Amp @ 208-277 VAC
Ballast (fluorescent) 16 Amp @ 120-277 VAC
Motors 1 H.P. @ 120 VAC, 2 H.P. @ 240 VAC
DC Loads 4 Amp @ 12 VDC, 2 Amp @ 28 VDC
WARNING
Electrical shock hazard. Risk of injury or death. Remove electrical power
at service panel before installing.
Risk of fire or burns from used battery. Do not recharge, disassemble, heat
above 100˚ C, crush, or incinerate the lithium battery. Keep battery out of
reach of children. Replace only with Panasonic type CR2 or equivalent
CR2 battery approved by Underwriters Laboratories (UL). Use of a different
battery type may present a risk of fire or explosion upon disposal of bat-
tery.
Risk of fire. Do not use timer to control devices that could have dangerous
consequences due to inaccurate timing, such as sun lamps, sauna, heat-
ers, crock pots, etc.
NOTICE
Follow local electrical codes during installation.
Risk of timer damage due to leakage if weak battery is not replaced promptly.
Dispose of used battery promptly per local regulations.
1 – Before Installing Switch Timer, Install and Check Battery
Before installing the switch timer into the wall, make sure the sup-
plied battery is installed and working.
1.
Open the access door to reveal the battery tray, located below the
ON/OFF keypad.
2.
If there is a pull tab at the battery tray, remove the tab to connect
the installed battery. Make sure battery tray is pushed fully into
place. Proceed to Step 6.
3.
If the battery was supplied loose, use a flat screwdriver to pry
loose the battery tray.
4.
Place the supplied "CR2" battery into the tray, observing + and
– markings on tray.
5.
Replace the battery tray into the switch timer.
6.
The display will initialize itself then flash "12:00 AM" in MANual
mode.
7.
Press the ON/OFF button. The switch timer should "click."
NOTE: If display doesn't flash "12:00 am", the battery may be dead.
Replace the battery before installing the switch timer.
2 – Install the Switch Timer
1.
Turn off power at the service panel by REMOVING FUSE or
TURNING THE CIRCUIT BREAKER OFF.
2.
Remove the existing wall switch.
3.
Trim building wires to 7/16" as shown.
If a Single Switch Setup:
a.
Connect one of the two wires from
the wall to the black wire from the
switch timer, using the twist con-
nectors provided.
b.
Connect the other wire from the
wall to the blue wire from the
switch timer, using the twist con-
nectors provided.
158EI13058
Self-Adjusting Wall Switch
NOTE: The RED wire is not used in single-switch installations.
Cap with a twist connector.
c.
Connect the GREEN wire to the grounding screw in the box. If a
plastic box, connect to ground as supplied.
d.
Make sure all twist connectors are tight.
If a 3-Way Switch Setup:
NOTE: The distance between
switch timer and remote switch
must not exceed 100 feet.
a.
Locate the COMMON wire
connected to first old switch. It
might be attached to a different
colored screw, or find mark-
ings on old switch.
b.
Connect BLACK wire from switch timer to COMMON wire, using
a twist connector.
c.
Connect the other two wires from the old switch to the Blue and
RED wires from the switch timer.
d.
Connect the GREEN wire to the grounding screw in the box. If a
plastic box, connect to ground as supplied.
e.
Using diagram #1 below. Identify and remove wire "C" from the
"Common" terminal of your existing remote switch.
DIAGRAM 1:
TYPICAL
LINE
EXISTING
2-SWITCH
SETUP
MAIN SWITCH
f.
Using diagram # 2 below, remove and reconnect wires "B" and
"C" to the "Common" terminal of your remote switch, using a
jumper wire, if necessary. Follow diagram # 3 below, if using a
new single-pole remote switch.
DIAGRAM 2:
2-SWITCH SETUP,
LINE
TIMER INSTALL
RE-USING EXISTING
REMOTE 3-WAY SWITCH
DIAGRAM 3:
LINE
2-SWITCH SETUP,
TIMER INSTALL USING
NEW SINGLE-POLE
REMOTE SWITCH
NOTE: For new construction or to replace a dimmer switch,
a lighted switch, or a 3-way switch without screw terminals, a
single-pole switch can be used at the remote location, as shown.
NOTE: If the building's wiring colors don't allow you to tell wire
"A" from "B," just pick one of the two wires and connect as if it is
wire "B." After the installation is complete, if the controlled light
or device will not turn on properly, simply reverse wires "A" and
"B." See Steps J and K for how to check.
7/16"
g.
Tuck wires into the timer wall box leaving room for the timer.
h.
Using screws provided, mount the switch timer into the wall box,
then install the wall plate.
BLACK WIRE
i.
Install the remote 3-way switch in its box and install wall plate.
Turn the power back on at the service panel.
j.
Make sure the switch timer displays "MAN" mode. Do the follow-
ing test with the remote switch in each of its 2 positions: Press the
BLUE WIRE
ON/OFF button on the switch timer several times. Each time that
you push the ON/OFF button, the switch timer should "click" and
RED WIRE
the controlled light or device (the "load") should turn on or off. If
(capped, not connected)
so, proceed to Step K.
Timer
RED WIRE
BLUE WIRE
WIRE FROM
"COMMON" OF
OLD SWITCH
BLACK WIRE
LOAD
"COMMON" TERMINAL
WIRE "A"
WIRE "C"
NEUTRAL
WIRE "B"
3-WAY
3-WAY
REMOTE SWITCH
LOAD
NEUTRAL
WIRE "C"
BLACK
BLUE
WIRE "B"
TIMER
JUMPER
RED
WIRE "A"
"COMMON" TERMINAL
3-WAY
NOT USED
REMOTE SWITCH
LOAD
NEUTRAL
BLUE
WIRE "B"
WIRE "C"
BLACK
TIMER
JUMPER
RED
WIRE "A"
SINGLE-POLE
REMOTE SWITCH

Advertisement

loading

Summary of Contents for Intermatic EI600 Series

  • Page 1: Troubleshooting Guide

    LIMITED FIVE-YEAR WARRANTY If within one (5) years from the date of purchase, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its sole option, free of charge. This war- ranty is extended to the original household purchaser only and is not transferable.
  • Page 2: Clear Any Existing Program

    If a Multiple Switch Timer Setup: Press ON/OFF to display HOUR (Fig. 5), then Multi-switch applications using the EI600 Series switch timer are press + until the correct hour and AM/PM are wired differently than when using conventional toggle switches. Read shown.