Switch functions in external load management
mode:
S2: configuration of bus ID 16
S4: configuration of bus IDs 1 to 15
S5: setting of leader or follower, front illumination
4.1
Configuration of maximum
(switch S1) and minimum (switch S3)
charging current (per Wallbox)
Rotary switch S1 – setting of the maximum charging
current from 6 A to 16 A
Rotary switch S3 – setting of the minimum charging
current from 6 A to 16 A
0
6 A (default setting, as-delivered state)
1
8 A
2
10 A
3
12 A
4
14 A
5 ... 9
16 A
4.2
Switch S2
Local load management: configuration of maximum
system current in the leader Wallbox
S2/1
S2/2
10 A
OFF
OFF
16 A
OFF
OFF
20 A
OFF
OFF
25 A
OFF
OFF
32 A
OFF
ON
35 A
OFF
ON
40 A
OFF
ON
50 A
OFF
ON
63 A
ON
OFF
80 A
ON
OFF
100 A
ON
OFF
125 A
ON
OFF
160 A
ON
ON
200 A
ON
ON
224 A
ON
ON
250 A
ON
ON
External load management: micro switch S4 is
without function in the Wallbox configured for
bus ID 16.
Bus-ID
S2/1
S2/2
0
OFF
OFF
4.3
Local load management: configuration of the
number of follower Wallboxes in the leader Wallbox
Follower
Wallboxes
No
follower
1
2
3
4
5
6
7
8
9
10
11
12
13
S2/3
S2/4
14
OFF
OFF
15
OFF
ON
Configuration of the bus ID of the individual follower
ON
OFF
Wallboxes:
ON
ON
Never assign double bus IDs.
OFF
OFF
The bus ID of the first follower Wallbox must
OFF
ON
begin with a 1.
ON
OFF
Bus-ID
ON
ON
Only
OFF
OFF
leader
OFF
ON
1
ON
OFF
2
ON
ON
3
OFF
OFF
4
OFF
ON
5
ON
OFF
6
ON
ON
7
8
9
10
11
S2/3
S2/4
12
OFF
ON
13
14
15
Switch S4
S4/1
S4/2
S4/3
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
S4/1
S4/2
S4/3
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
English
S4/4
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
S4/4
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON