Vacuum Laundry Pipe Laundry Jet specifies 6" SDR35 White Solvent Weld PVC pipe and fittings. This piping is light weight to make install quick and easy. PVC piping is designed to have a smooth transition in between fittings and connections which ensures that clothing, bedding and towels will travel smoothly to the laundry room.
Contents 2 Contents Laundry Jet Swift ISense Port Pipe Components All Fittings are 6" SDR35 White Solvent Weld 6 Inch Wye 6 Inch 45° Elbow 6 Inch Coupler 6 Inch Cleanout 6 Inch 90° 6 Inch Swept 90° ISense Sheetrock Template +1.800.867.4580...
Pipe Installation Standards 3.1 Pipe Installation Overview Pipe Installation Standards Required Piping Installation Standards All joints must use a minimum entry angle of 45 degrees with a break distance of 18 Inches ▪ (460 MM). See Image below. Pipe cuts must be straight and de burred before seating. ▪...
Port Drop Installation 3.2 Pipe Installation Overview Port Drop Installation Mount port 90 using the Port 90 Mount Bracket. See Page 11 for Port 90 Installation. Use a ▪ standard SDR 6" Swept 90 for your Port Drop Installation. Block and strap drop line at midway point +1.800.867.4580 sales@laundryjet.com...
Port 90 Installation 3.3 Pipe Installation Overview Port 90 Installation Port 90 must be installed with front face of Port 90 flush with the finished face of interior ▪ wall. Port 90 must be installed on a plum horizontal port drop line. ▪...
Jet Pack Pipe Drop 3.4 Pipe Installation Overview Jet Pack Pipe Drop Directly above your unit on the ceiling you will place your pipe drop template (match ▪ template orientation to the machine). Use this to set your pipe drops in the proper position. Install a standard swept 90 drop to each port using a swept 90 elbow.
ISense Port Installation Step 1 - Port 90 Mount Bracket Port 90 Mount Bracket Use the Port 90 Mount Bracket to align and secure the Port 90 to the frame ▪ Set Port height ▪ Attach 2 pipe clamps ▪ Set elevation screws ▪...
ISense Port Installation 4.2 Step 2 - ISense Sheetrock Template Sheetrock Template Install sheetrock over the Port 90 Mount Bracket ▪ Trim around outside edge of the Port 90 and remove material ▪ Position the round portion on the back of the template into the Port 90 ▪...
ISense Port Installation 4.3 Step 3 - ISense Port Assembly ISense Port Assembly Connect RJ45 male connector to female connector on back of port ▪ Remove the front logo plate and position the Port into place ▪ Align Port for final adjustment using a level ▪...
Jet Pack Installation 5.1 Jet Pack Installation Blower Pod Installation If possible, install the Blower Pod into the unit after the jet pack has been mounted to the wall. If there is not sufficient room to install the blower pod first, follow instructions below and then proceed with the jet pack installation.
Page 18
Jet Pack Installation 5.1 Jet Pack Installation Jet Pack Installation ▪ Using a stud finder, locate mounting stud position. Mark Jet Pack installation position on the intended mount wall. ▪ Draw a vertical line down the center of your mount stud at the elevation of your cabinet mount cutout.
Page 19
Jet Pack Installation 5.1 Jet Pack Installation Jet Pack Installation Ensure that the Jet Pack is not plugged in. ▪ Connect all the RJ45 cables as shown above. ▪ Make sure all ISense Ports are fitted and properly connected and ready to run ▪...
Lifetime Limited Warranty Laundry Jet is protected by a 3 year limited lifetime warranty. This warranty is valid from the date of purchase, for as long as you are the original owner, the system remains at its original place of installation and as long as the warranty form has been completed and submitted on our website: http://www.laundryjet.com/warranty...