2.2

Function

The device is suitable for applications in virtually all industries for filling and water level measurement, especially for fresh
water, wastewater and salt water. The slim construction design allows the use especially at confined space conditions, e.g. at
bore holes and wells with small diameter.
The high precise, long term stable and robust ceramic measuring cell, the stainless steel enclosure and the thick-walled,
length stable extension cable with highly stressable steel core ensures reliable precise measuring values and allows the
operation also at demanding environmental conditions, e.g. low temperatures, high shock and vibration loads or at
problematic liquids.
The hydrostatic liquid pressure acts directly (dry system) via the process diaphragm to the capacitor at the back side. The
pressure causes there a capacitance change which is converted into a corresponding output signal.
For optional measuring the temperature, an integrated long-term stable platinum temperature sensor is used. The measured
temperature value can be read out at the version 09-V (RS485 Modbus-RTU) by the digital interface or the resistance signal
can be evaluated at the version 09-A (current 4...20mA FSK) in parallel to the pressure conditioned analogue current signal
per 3-wire-technology.
The parameterization and operation can be made by the integrated wired interface.
2.3

Configuration

The device consists on the components:
① Measuring cell
② Electronic enclosure
2.4

Product label

The type label contains the most important data for identification and use of the instrument.
1
HP4SCS01V005A00R1K-10000
S/N: 482569/2022
2
pi
= 0..1bar
2
4
3
Io
= 4..20mA
4
1 = L+ / Cio
Cio
= FSK
3
2 = nc
Us
3 = L- / Io
4 = nc
① Type code
84307 Eggenfelden / Germany
www.acs-controlsystem.com
② Serial number
③ Technical data
Illustration exemplary
2.5

Packaging, transport, storage

The device is protected by packaging. It can handle normal loads during transport. Transport must be carried out in due
consideration of the notes on the transport packaging.
Nonobservance of these instructions can cause damage to the device.
The delivery must be checked for completeness and possible transit damage immediately at receipt. Ascertained transit
damage or concealed defects must be appropriately dealt with.
Dispose of the packaging material via specialized recycling companies.
Up to the time of installation, the packages must be left closed and, unless otherwise indicated, must be stored only under
the following conditions:
Not in the open
Dry and dust free
Not exposed to corrosive media
Protected against solar radiation
Avoiding mechanical shock and vibration
Storage and transport temperature -20...+85°C
Relative humidity 20...85%
ACS-CONTROL-SYSTEM GmbH | Lauterbachstr. 57 | 84307 Eggenfelden | Germany
4
3
③ Extension cable
④ Ventilation/pressure compensation
5
6
1
④ Assignment
⑤ Safety notes
⑥ Approvals
2
info@acs-controlsystem.de | +49 (0) 8721/9668-0
1
5