5. The maximum voltage of the system should be less than the maximum certified voltage and less than the maximum
input voltage of the inverter and of the other electrical devices installed in the system. To ensure this, the open circuit
voltage of the array needs to be calculated at the lowest ambient temperature for the location.
6. Before connecting the components, check the appearance of the material to verify that there is no problem.
The connector itself cannot be damaged, have fractures, or have other issues that cause an electrical hazard.
7. Please see the table below for which indicates the connectors to use on the module and the allowable
mating connector.
Table 6: PV Module I Connector Information
No
Manufacturer
Zhe Jiang Jiaming
1
Tianheyuan
Zhe Jiang Jiaming
2
Tianheyuan
3
Multi-Contact USA
4
Multi-Contact USA
Amphenol Industrial
5
Operations
Amphenol Industrial
6
Operations
Amphenol Industrial
7
Operations
8
Zhe Jiang Renhe
The Model of
the Connector
Manufacturer
PV-JM601
PV-JM601A
PV-KST4/6II-UR (male)
PV-KBT4/6II-UR (female)
PV-KST4-EV02/6II-UR (male)
PV-KBT4-EV02/6II-UR (female)
UTXCFA4AI
Helios H4 Assembled
Helios HH4 Assembled
05-6-2q
Allowable Mating
Connector
PV-JM601 and PV-JM601A
PV-JM601 and PV-JM601A
PV-KST4/6II-UR (male)
PV-KBT4/6II-UR (female)
PV-KST4-EV02/6II-UR (male)
PV-KBT4-EV02/6II-UR (female)
UTXCFA4AI
Helios H4 Assembled
Helios HH4 Assembled
05-6-2q
Manufacturer
Website
www.jmthy.com
www.jmthy.com
http://ec.staubli.com/
downloads/
http://ec.staubli.com/
downloads/
www.amphenol-
Solar.com
www.amphenol-Solar.
com
www.amphenol-Solar
.com
www.renhesolar.com
/cn/index.php
14