Page 1
The controller has 16 form-C contacts for load switching. In addition, 2 digital inputs may be used for tamper and UPS status monitoring. The sub-controller requires either 12Vdc or 12Vac for power. Imron Corporation 15375 Barranca Pkwy, Suite B-106 Irvine, CA 92618 Phone 949-341-0947 Fax 949-341-0949...
Page 2
The interface allows multi-drop communication on a single bus of up to 4,000 feet (1,200 m). Use twisted pair(s) (minimum 24 AWG) with shield for the communication. Install the following jumpers for the RS-485 interface according to the selected configuration: Imron Corporation 15375 Barranca Pkwy, Suite B-106 Irvine, CA 92618 Phone 949-341-0947 Fax 949-341-0949...
Page 3
Switches 1 to 5 select the devices communication address. Switches 6 to 7 select the communication baud rate. Communication on the RS-485 serial port is asynchronous, half-duplex with 1 start bit, 8 data bits and 1 stop bit. Imron Corporation 15375 Barranca Pkwy, Suite B-106 Irvine, CA 92618 Phone 949-341-0947 Fax 949-341-0949...
Page 5
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Imron Corporation 15375 Barranca Pkwy, Suite B-106 Irvine, CA 92618 Phone 949-341-0947 Fax 949-341-0949...
Page 6
This product is not intended for, nor is rated for operation in life-critical control applications. Imron Corporation is not liable under any circumstances for loss or damage caused by or partially caused by the misapplication or malfunction of the product. Imron Corporation's liability does not extend beyond the purchase price of the product.
Need help?
Do you have a question about the S0-16 and is the answer not in the manual?
Questions and answers