Advertisement

Quick Links

Azure IC2 Hardware Manual
03/02/2022
© 2022 IMRON CORPORATION
All rights reserved. No parts of this work may be reproduced in any form or by any means - graphic, electronic, or
mechanical, including photocopying, recording, taping, or information storage and retrieval systems - without written
permission.
While every precaution has been taken in the preparation of this document. Author assumes no responsibility for errors or
omissions, or for damages resulting from the use of information contained in this document or from the use of programs
and source code that may accompany it. In no event shall the publisher and the author be liable for any loss of profit, or any
other commercial damage caused or alleged to have been caused directly or indirectly by this document.

Advertisement

Table of Contents
loading

Summary of Contents for Imron Corporation Azure IC2

  • Page 1 Azure IC2 Hardware Manual 03/02/2022 © 2022 IMRON CORPORATION All rights reserved. No parts of this work may be reproduced in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage and retrieval systems - without written permission.
  • Page 2 IC2 Hardware Manual 2-Door Intelligent Network Controller by IMRON Corporation...
  • Page 3 CE Compliant UL & ULC Recognized • UL294 • UL294B • UL1076 & ULC/ORD 1076 • UL2610 2022 IMRON CORPORATION This manual contains confidential information and may only be reproduced or distributed with the written consent of IMRON CORPORATION...
  • Page 4: General Features

    1 Buzzer Output (open collector) per reader port • Buzzer output can be repurposed for 2-wire LED control 2022 IMRON CORPORATION This manual contains confidential information and may only be reproduced or distributed with the written consent of IMRON CORPORATION...
  • Page 5 IMRON IC2 Hardware Manual Part II Hardware Layout Hardware Layout Figure 2.1: IC2 Diagram 2022 IMRON CORPORATION This manual contains confidential information and may only be reproduced or distributed with the written consent of IMRON CORPORATION...
  • Page 6: Terminal Connectors

    Input 2 Input 2 TB5-1 Input 2 Return IN2G TB6-4 Input 3 Input 3 TB6-3 Input 3 Return IN3G 2022 IMRON CORPORATION This manual contains confidential information and may only be reproduced or distributed with the written consent of IMRON CORPORATION...
  • Page 7: Relay Output Connections

    OUT 4 - NO TB9-5 Common OUT 4 - C Relay K4 Connection TB9-6 Normally Closed OUT 4 - NC 2022 IMRON CORPORATION This manual contains confidential information and may only be reproduced or distributed with the written consent of IMRON CORPORATION...
  • Page 8: Reader Connections

    Reader 2 Device Connections Beeper TB11-4 (Buzzer) Control Green LED TB11-5 Control TB11-6 (Reader Power) Table 2.1: IC2 Terminal Connections 2022 IMRON CORPORATION This manual contains confidential information and may only be reproduced or distributed with the written consent of IMRON CORPORATION...
  • Page 9 Note: RS485 termination jumpers (J2, J3, J4, & J6) are shipped from the factory in the OFF (termination disengaged) position. Only turn ON termination if the IC2 is at the end of the serial bus. 2022 IMRON CORPORATION This manual contains confidential information and may only be reproduced or distributed with the written consent of IMRON CORPORATION...
  • Page 10: Microsd Card

    Relay OUT 2 (K2): ON = Energized Relay OUT 3 (K3): ON = Energized Relay OUT 4 (K4): ON = Energized 2022 IMRON CORPORATION This manual contains confidential information and may only be reproduced or distributed with the written consent of IMRON CORPORATION...
  • Page 11 “Specifications” section for more information. The coin cell battery power level is monitored and a low battery condition will generate an event message. 2022 IMRON CORPORATION This manual contains confidential information and may only be reproduced or distributed with the written consent of IMRON CORPORATION...
  • Page 12 Eight holes are provided for mounting the IC2. Mount at least 0.25 inches above the conductive surfaces. One mounting hole is plated for connecting to Chassis (Earth) ground. Figure 2.3: IC2 Mounting Holes [inches (mm)] 2022 IMRON CORPORATION This manual contains confidential information and may only be reproduced or distributed with the written consent of IMRON CORPORATION...
  • Page 13 IMRON Corporation recommends the use of isolated, continuous power supplies only. In the case of over-current, solid-state fuses integrated on the IC2 panel will ‘trip’ to protect the components of the panel.
  • Page 14 Match the polarities; connect positive (+) to positive and negative (-) to negative. Wiring recommendation of 24 AWG, shielded twisted pair. Wiring requirements satisfied by Belden 9841 or equivalent. © 2022 IMRON CORPORATION This manual contains confidential information and may only be reproduced or distributed with the written consent of IMRON COPORATION...
  • Page 15 Serial Bus Topology (Controller at End) - Correct “Star” Topology - Incorrect “T stub” Topology - Incorrect Figure 3.2: RS-485 Bus Topologies © 2022 IMRON CORPORATION This manual contains confidential information and may only be reproduced or distributed with the written consent of IMRON COPORATION...
  • Page 16 Wire these inputs with 24 AWG minimum. See “Unsupervised” in Section 3.6.1 wiring diagram. Figure 3.3: Cabinet Tamper & Power Fault Wiring © 2022 IMRON CORPORATION This manual contains confidential information and may only be reproduced or distributed with the written consent of IMRON COPORATION...
  • Page 17: Reader Ports

    LED and buzzer may not function on the reader. Figure 3.4: IC2 Wiegand Reader Wiring © 2022 IMRON CORPORATION This manual contains confidential information and may only be reproduced or distributed with the written consent of IMRON COPORATION...
  • Page 18: Supervised Alarm Inputs

    The following wiring diagram shows some of the pre-defined termination resistor configurations. © 2022 IMRON CORPORATION This manual contains confidential information and may only be reproduced or distributed with the written consent of IMRON COPORATION...
  • Page 19: Door Strike Wiring

    MOV AC Strike ratings. Be sure to use a UL approved MOV. © 2022 IMRON CORPORATION This manual contains confidential information and may only be reproduced or distributed with the written consent of IMRON COPORATION...
  • Page 20 485 (OSDP readers). Access Points can also use two readers in a “paired” configuration. 3.8.2 Door Contact & Exit Pushbutton/REX Inputs © 2022 IMRON CORPORATION This manual contains confidential information and may only be reproduced or distributed with the written consent of IMRON COPORATION...
  • Page 21: Door Strike

    A Fail-Secure strike uses electrical current to unlock the door; meaning in a power failure situation, the door will default to a locked state. © 2022 IMRON CORPORATION This manual contains confidential information and may only be reproduced or distributed with the written consent of IMRON COPORATION...
  • Page 22: Troubleshooting

    When the IC2 encounters an unrecoverable state please perform a factory reset by pressing the reset button on board. Please contact IMRON Corporation support for maintenance if the IC2 is not working properly. © 2022 IMRON CORPORATION This manual contains confidential information and may only be reproduced or distributed with the written consent of IMRON COPORATION...
  • Page 23: Specifications

    Note: When connecting an inductive load like a magnetic strike, it is recommended to derate the relay’s current rating by 50%. © 2022 IMRON CORPORATION This manual contains confidential information and may only be reproduced or distributed with the written consent of IMRON COPORATION...
  • Page 24 Dim: 8 in. (203.2 mm) W x 6 in. (152.4 mm) L x .75 in. (19.05 mm) H Mechanical Weight: 0.6 lbs. (272.2g) © 2022 IMRON CORPORATION This manual contains confidential information and may only be reproduced or distributed with the written consent of IMRON COPORATION...
  • Page 25 Product evaluated as a recognized component by UL and is not suitable to be used as a Listed subassembly. Products are for user with listed access control or proprietary burglar alarm control units/system. © 2022 IMRON CORPORATION This manual contains confidential information and may only be reproduced or distributed with the written consent of IMRON COPORATION...