Mounting The Xlr8 Scan Head; Interconnections - Nutfield Technology XLR8 Manual

Table of Contents

Advertisement

Nutfield Technology
To Install a
1) Before installing a lens onto the Scan Head, visually inspect the lens surface for any
Lens:
2) If the lens is dirty, clean the lens as described in the lens cleaning instructions under
3) If there is a protection glass, make sure it is clean, and then place it over the front of the
4) The lens assembly is screwed into the Scan Head. Carefully and securely mount the lens to
To Remove
Reverse the above procedure.
a Lens:

4.2 Mounting the XLR8 Scan Head

There are several ways to mount the XLR8 Scan Head. For mounting with the smallest and
least amount of hardware, the head may be directly mounted using the mounting holes
provided on the input plate of the head. See the outline drawing below.
In situations where the head is to be mounted to an existing mounting hole pattern, such as an
industry standard mounting pattern, it may be necessary to use in intermediate interface plate.
This plate is available as an option from Nutfield Technology. See the outline drawing below
with interface plate. Contact your sales representative for further information.
The use of some output objective lenses may require the use of an intermediate interface plate.
This is usually the case when the lens has a diameter which is too large and protrudes beyond
the input plate of the head. Most single CO2 lenses and smaller YAG lenses do not require an
intermediate interface plate. Some examples of lenses requiring an intermediate interface plate
are the YAG f=163 and f=254 lenses. Contact your sales representative for further information.
1) The Scan Head requires a mounting flange that will match the mounting pins and holes on
2) Line up the XLR8 Scan Head module dowel holes with the dowel pins, which protrude
3) Install the XLR8 Scan Head module onto the pins.
4) Insert two M6 size button head screws into the holes of the mounting flange. The screw
5) Using a hexagonal wrench, tighten the two screws. Alternate tightening the two screws so

4.3 Interconnections

The following figure depicts the connection of the XLR8 Scan Head and the PC-interface
boards to the various other Customer-supplied parts of the system. Typically there is a 25-pin
D connector, which carries all signals and a 9-pin D connector to carry power. In some
instances, the 25-pin connector can be configured to carry both signals and power.
91-0021 Rev. D
evidence of damage, i.e.; cracked lens, cracks on the edges of the lens, scratches on the
lens surface, etc.
MAINTENANCE. Do not rest any objects on top of the lens as this may result in
damaging the lens.
lens. Screw the Mounting Ring into the lens flange until it is tight over the Protection
Glass. Hand-fit lens protection cap onto the lens assembly.
the XLR8 Scan Head. (DON'T CROSS-THREAD THE LENS ASSEMBLY). The lens
should be screwed on completely.
the Beam Input side of the assembly. The previous figure and the outline drawings, in
Appendix C, can be used to determine the dimensions for manufacturing a mounting
flange.
from your mounting flange.
length should be long enough to provide three or more full turns into the tapped holes.
that the XLR8 Scan Head comes together evenly onto the mounting flange.