ILMEG X-150 Installation And Operating Instructions Manual

Advertisement

Quick Links

X-150
Dust Collector System
Installation and operating instructions
ILMEG Products AB, Sweden. Phone +46 155 220270 Fax +46 155 220277 mail: info@ilmeg.se web: www.ilmeg.se
We reserve the right to change the specification without prior notice.

Advertisement

loading

Summary of Contents for ILMEG X-150

  • Page 1 X-150 Dust Collector System Installation and operating instructions ILMEG Products AB, Sweden. Phone +46 155 220270 Fax +46 155 220277 mail: info@ilmeg.se web: www.ilmeg.se We reserve the right to change the specification without prior notice.
  • Page 2: Safety Regulations

    Always replace worn or damaged signs. Warning If the air coming out of the suction fan contains dust. Stop immediately the X-150 and check for leakages. Never operate with dust coming out of the suction fan since the suction fan will be worn out.
  • Page 3: Installation Mechanical Installation

    Installation Mechanical installation Make sure the mechanical bracket used for the X-150 is sufficient to carry the full weight of the dust collector in rock drilling applications. Correct mounting is as close to the feed beam/ rock drill as possible to reduce the suction hose length. The suction hose should be as straight as possible.
  • Page 4: Hydraulic Installation

    Hydraulic installation Contact a hydraulic specialist to design the hydraulic circuit for your application. The hydraulic hoses for the pressure and return line must have the capacity of 45 l/min and 200 Bar pressure without excessive counter pressure. Recommended size is minimum Ø ½” or Ø...
  • Page 5 Air pressure installation for the filter cleaning system Connect air supply for the filter cleansing function of the dust collector. Recommended pressure is 7 BAR or 100 PSI. To safeguard full filter cleansing effect a Ø 1” or Ø 25 mm hose is recommended. Warning Always use proper quality of pneumatic hoses and fittings to reduce risk of leakage.
  • Page 6: Electrical Installation

    Press “OK” and increase or decrease parameter with the “+” or “-“ button. Press “OK” again to confirm the new parameter. The new parameter is now active and stored in the memory of the X-150 Control system Open the cover of the control system.
  • Page 7 By pressing once on “A” the menu for setting the parameters / times during the drilling operation appears. Pause means the time between the cleaning pulses. (see i-clean above) Factory setting is: Pause: 1000 x 10ms = 10 seconds Delay means time to close one of the air valves.
  • Page 8 The suction hose recommended for the X-150 is Ø 6“ or Ø 150 mm On the X-150 the suction hose is inserted in the rubber bushing, inlet reduction, and tightened on the outside to avoid unnecessary wear on the steel inlet.