Summary of Contents for ILMEG X-150

  • Page 1 X-150 Dust Collector System Service and maintenance instructions ILMEG Products AB, Sweden. Phone +46 155 220270 Fax +46 155 220277 mail: info@ilmeg.se web: www.ilmeg.se We reserve the right to change the specification without prior notice.
  • Page 2: Safety Regulations

    Always replace worn or damaged signs. Warning If the air coming out of the suction fan contains dust. Stop immediately the X-150 and check for leakages. Never operate with dust coming out of the suction fan since the suction fan will be worn out.
  • Page 3: Service And Maintenance Schedule

    Service and Maintenance Schedule To secure maximum productivity and avoid unnecessary downtime due to breakdown and repair activities, preventive maintenance in accordance with the schedule below is recommended. Service interval Activity Actions During operation Check for dust in the air from the suction fan Stop immediately and check for leakages Daily...
  • Page 4 Check that the pneumatic hoses, electrical cables and connectors are not damaged. 7. Check that no dust is coming out through the fan while drilling. If dust is coming through, stop the operation immediately. A leakage in the filter house or a filter may be damaged and need to be replaced.
  • Page 5 Changing inlet/diffuser if worn out. 14. Remove screws (N) holding the inlet. 15. Take out the whole inlet/diffuser (O), (it is one unit) 16. Check the gasket, if worn out - change, otherwise place it properly on the new inlet to prevent any leakage.
  • Page 6: Troubleshooting

    Trouble shooting Problem Possible Cause Actions Vibrations on the Stop and check the suction fan Change the suction fan if dust collector necessary Suction capacity is Check for leakages Tighten or change components if reduced necessary Suction capacity is Suction hose is blocked Clean the suction hose or change reduced the suction hose...
  • Page 7 Internally: Unlock and lift up the lid. Secure the lid with the metal holder (A). 5. Check valve plate (B) for leakage. 6. Check that pneumatic cylinders (C) are working properly. 7. Check that all cable connections (D) are fitted correctly. 8.
  • Page 8 Change of the fan impeller on the X-150 Change the hydraulic motor on the X-150 Unscrew the bolts on the top of the fan. Lift the top with a lifting devise and put it upside-down on a working table. Unscrew the two bolts that tighten the conical bushing.
  • Page 9 The bushing must be raised minimum 5 mm to come loose. Lift the impeller from the motor axle. If changing the motor: Unbolt the hydraulic motor and replace with a new motor. Assembly: To achieve the best result it is of greatest importance that the conical bushings and the motor axle are clean and not greased.
  • Page 10 Install the new impeller on the motor axle and install the conical bushing with the smaller diameter down in the position where the two bolts can later be installed. Use for instance a brass tool gently to push the bushing down as much as possible. Do not use excessive force.
  • Page 11 Install the fan top on the fan housing and make sure the top is centred over the nuts in the fan housing. Install 4 bolts and tighten them. Lift the complete fan unit and check from underneath that the fan is not colliding with the suction tube in the centre.
  • Page 12 Install the rest of the bolts on top of the fan. ILMEG Products AB, Sweden. Phone +46 155 220270 Fax +46 155 220277 mail: info@ilmeg.se web: www.ilmeg.se We reserve the right to change the specification without prior notice.