PRE-INSTALLATION ASSEMBLY REQUIREMENTS

BEFORE INSTALLATION, ENSURE THAT YOUR DOOR IS PROPERLY BALANCED AND RUNNING
SMOOTHLY. ALSO ENSURE THAT THE LIMIT BRACKETS (SUPPLIED) ARE INSTALLED AND
SECURED PROPERLY. BUMPER/PUSHER SPRINGS MAY BE USED IN PLACE OF, OR IN ADDITION TO
LIMIT BRACKETS FOR PULSE OPERATORS, BUT MUST BE INSTALLED PRIOR TO OPERATION.
Operator Mounting Requirements
Pulse operators are mounted directly on the door shaft. Before installing the operator, please en-
sure following criteria is met:
The door is well balanced, is tested for
smooth functioning without any unusual
noise.
Provided Limit Brackets must be installed
4"-5" past door's desired open position (and
within allowable maximum cable height) to
prevent the doors from over-travel. (See Fig.
1A)
The door has a solid keyed shaft with a
minimum exposed length of 4.5" on the
operator side.
Clearance of at least 12" horizontally from
the side of the door (or 9" from end of shaft),
and 24" vertically below the shaft. There
is adequate structural support surface to
FIGURE: 1
securely install the torque arm mounting
bracket, the torque arm and the junction
box. For more details, see mounting
installation instructions
FIGURE: 1A
Fig: 1 & 7.
Magnet on
Mounting space for the operator Control
this side
Encoder
Panel (Min. 5 ft. from ground level, within
clear sight of the door but far enough away
as to prevent users from contacting moving
parts).
Left Hand Mounting:
FIGURE: 2
The factory default mounting as shown
(Shown in Fig: 2) is for left-hand side of the
door, hence no modification is required.
5