VII Troubleshooting
Problem
A. little or no material flow
B. material leaking
C. atomization is too coarse
D. spray jet pulsates
E. pattern runs, sags or remains wet
F. too much over-spray
G. pattern is very light and splotchy
H. large cloud of disinfectant
I. disinfectant not drying
J. disinfectant drying too quickly
K. battery pack not charging
Cause
1. nozzle clogged
2. suction tube clogged
3. material volume setting turned too far to the right
4. suction tube loose
5. container is loose
1. nozzle loose
2. nozzle worn
3. nozzle seal worn
4. material build-up on spray pattern dial and nozzle
5. atomizer used or stored in an inverted or sideways
orientation
1. material volume setting too far to the left
2. nozzle clogged
3. too little pressure build-up in container
1. material in container is depleted
1. applying too much material
1. atomizer too far from target area
2. too much material applied
1. moving the atomizer too fast
1. atomizer too close to target area
1. atomizer too close to target area
1. atomizer too far away from target area
1. charger not plugged into live outlet
2. pack too cold to charge, green LED on charger is on
3. pack too hot to charge, green LED on charger is on
4. defective pack
5. defective charger
Freedom XF102- User Manual
Solution
1. clean
2. clean
3. turn to the left
4. insert
5. tighten the container
1. tighten
2. replace
3. replace
4. clean
5. disassemble atomizer from motor/blower
assembly and used compressed air to remove liquid
from atomizer assembly. If liquid has entered motor
/blower used compressed air to remove all liquid and
allow to dry overnight. Replace motor/blower
assembly if erratic operation occurs after drying
overnight.
1. turn to the right
2. clean
3. tighten container
1. refill
1.adjust material flow or increase movement of
atomizer
1. reduce distance
2. turn material volume setting to right
1. adjust material flow or decrease movement of
atomizer
1. move atomizer away from target area
and reduce disinfectant flow
1. move further away (4 feet or greater)
1. move closer
1. plug charger into outlet and ensure green LED is on
2. move pack and charger to warm location, 60-80°F.
Pack will charge upon reaching a safe temperature.
3. move pack and charger to cool location, 60-80°F.
Pack will charge upon reaching a safe temperature.
4. try another charger. If still not charging, replace
pack
5. try another pack. If still not charging, replace
charger