BATTERY ANALYSIS AND ERROR REPORTING
In case of anomaly the charger can report the following indications:
DISPLAY SIGNALING
PROTECTION
The chargers are equipped with following safety functions to ensure maximum safety during the use
and operation of the device.
Full protection against sparks
Short circuit protection
Voltage compensation
Overheat protection
Reverse polarity protection

MAINTENANCE

When not in use the charger should be kept in a dry area. For cleaning the external body of the
charger, disconnect the appliance and use a soft cloth.
CAUSE
The
output
clamps
connected to the battery.
Reverse polarity.
Battery with too low voltage. (You are trying
to charge a 12Volt battery with charger set
to 24V).
Battery with too high voltage. (You are
trying to charge a 24Volt battery with
charger set to 12V).
Charger in error.
After a certain period of time the battery is
unable to absorb current.
Battery recovery failed after a full cycle of
desulfation.
Disconnected cables, short circuit cables.
Battery completely short circuit.
REMEDY
are
improperly
Position the clamps correctly and start the
charging process again. (See HOW TO USE
THE BATTERY CHARGER)
Check the battery voltage.
The battery may be defective. Consult the
nearest Battery Service Center.
Have the charger checked by the nearest
Service Center.
The battery may be defective. Consult the
nearest Battery Service Center.
The battery may be defective. Consult the
nearest Battery Service Center.
Position the pliers correctly and resume the
battery charge; (see paragraph "how to use
the charger").
The battery may be defective. Consult the
nearest Battery Service Center.