2.
INTRODUCTION
MORI HR NEXT is a alternate flow fan with heat retention, designed to ensure adequate ventilation in enclosed environments without energy losses.
It is recommended that two units are installed in a pair: when one unit is extracting, the other is supplying air.
The pair of units can be installed in the same room or in different rooms (i.e. living-room and bedroom). The unit is suitable for installation on an outside
wall.
The unit should operate continuously, and only stopped for maintenance or service.
When heat exchange is not useful (for example in mid-seasons when indoor and outdoor temperatures are similar), or when heat
exchange is not recommended (for example with the option "summer free cooling"), it is recommended to set the unit in "extract-only"
or "intake-only" mode and NOT to switch it off.
Technical Specifications
Design front cover (A) removable for cleaning without the use of tools.
Inner ventilation unit (B) and wall support base (D) made of high quality, impact and UV-resistant ABS, colour RAL 9010.
Integrated multi-colour led (C ) to obtain a visual feedback of the unit status.
Smart humidity control.
Integral temperature sensor for the automatic management of the inversion time (comfort mode).
Automatic anti-frost protection to prevent frost building up on the heat exchanger.
Wall support base (D) provided with a magnet "coupling/uncoupling" system which allows the ventilation unit to be removed from its base
during maintenance.
Back-up touch button (E) at the side of the ventilation unit.
Unique design winglet-type impeller, providing enhanced aerodynamic properties, low noise and increased efficiency.
High efficient reversible EC motor with integral thermal protection, mounted on sealed for life high quality ball bearings.
Designed for continuous reversible running.
Telescopic pipe (F) adaptable to the wall thickness.
Antimortar cap designed to be used also as template during the installation of the wall support base.
Regenerative heat exchanger with ceramic core (G) with high thermal efficiency, equipped with washable anti-dust filters (H).
External grille (I) made of high quality, impact and UV-resistant ABS, colour RAL 9010, with anti-insect net and water drip guard.
Infra-red remote controller with touch technology, LCD display and wall base supplied as standard. Made from ABS, RAL 9010.
The unit is double insulated: no earth connection is required.
No need of condensation drainage system.
IPX4 degree of protection.
Power supply 220V to 240V~ 50Hz.