homevent MORI HR NEXT Installation & Maintenance Manual

homevent MORI HR NEXT Installation & Maintenance Manual

Alternate flow supply & extract fan with heat retention
Hide thumbs Also See for MORI HR NEXT:

Advertisement

Quick Links

Installation &
Maintenance Manual
MORI HR NEXT
Alternate Flow Supply & Extract
Fan with Heat Retention
Read this manual carefully before using the product and keep it in a
safe place for reference.
This product was constructed up to standard and in compliance with regulations
relating to electrical equipment and must be installed by technically qualified
personnel. The manufacturer assumes no responsibility for damage to persons or
property resulting from failure to observe the regulations contained in this booklet.
PRECAUTIONS FOR INSTALLATION, USE & MAINTENANCE
The device should not be used for applications other than those specified in this manual.
After removing the product from its packaging, verify its condition. In case of doubt, contact a qualified technician. Do not leave packaging
within the reach of small children or people with disabilities.
Do not touch the appliance with wet or damp hands/feet.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the
hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Do not use the product in the presence of inflammable vapours, such as alcohol, insecticides, gasoline, etc.
If any abnormalities in operation are detected, disconnect the device from the mains supply and contact a qualified technician immediately. Use
original spare parts only for repairs.
The electrical system to which the device is connected must comply with regulations.
Before connecting the product to the power supply or the power outlet, ensure that:
- the data plate (voltage and frequency) correspond to those of the electrical mains
- the electrical power supply/socket is adequate for maximum device power. If not, contact a qualified technician.
The device should not be used as an activator for water heaters, stoves, etc., nor should it discharge into hot air/fume vent ducts deriving from
any type of combustion unit. It must expel air outside via its own special duct.
Operating temperature: -20°C up to +50°C.
The device is designed to extract clean air only, i.e. without grease, soot, chemical or corrosive agents, or flammable or explosive mixtures.
Do not leave the device exposed to atmospheric agents (rain, sun, snow, etc.).
Do not immerse the device or its parts in water or other liquids.
Only turn off the power supply to the unit whenever a malfunction is detected or in the case of inspection, cleaning or maintenance. Prolonged
and/or repeated power interruption to the unit (any period more than 72 hours) can create a health and safety.
For installation an omnipolar switch should be incorporated in the fixed wiring, in accordance with the wiring regulations, to provide a full
disconnection under overvoltage category III conditions (contact opening distance equal to or greater than 3mm).
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Do not obstruct the fan or exhaust grille to ensure optimum air passage.
Ensure adequate air return/discharge into/from the room in compliance with existing regulations in order to ensure proper device operation.
If the environment in which the product is installed also houses a fuel-operating device (water heater, methane stove etc., that is not a "sealed
chamber" type), it is essential to ensure adequate air intake, to ensure good combustion and proper equipment operation.

Advertisement

Table of Contents
loading

Summary of Contents for homevent MORI HR NEXT

  • Page 1 Installation & Maintenance Manual MORI HR NEXT Alternate Flow Supply & Extract Fan with Heat Retention Read this manual carefully before using the product and keep it in a safe place for reference. This product was constructed up to standard and in compliance with regulations relating to electrical equipment and must be installed by technically qualified personnel.
  • Page 2 INTRODUCTION MORI HR NEXT is a alternate flow fan with heat retention, designed to ensure adequate ventilation in enclosed environments without energy losses. It is recommended that two units are installed in a pair: when one unit is extracting, the other is supplying air.
  • Page 3: Operation

    OPERATION Remote Controller The unit is supplied with an infrared remote controller (K) as standard, as well as its support base (L) which can be wall mounted. A magnet keeps the controller attached to the base. The controller is equipped with an LCD display to visualise the setting to be transferred to the unit; anytime a touch button is pressed, the setting shown on the LCD display is transferred to the unit.
  • Page 4: Ventilation Unit

    VENTILATION UNIT When switched on the unit emits a long acoustic signal. Through the IR controller the following functionalities can be activated/deactivated. When one setting is transferred to the unit, a short acoustic signal is emitted and a green led flashes. Acoustic Functionality Description Controller Button...
  • Page 5: Back Up Button

    Antifrost This functionality prevents frost building up on the heat exchanger due to extremely cold air. When it is activated, the Fixed Red unit runs in extract only at speed 1, for 30 minutes. Acoustic signal Any time a setting is transferred from the controller to the unit, a short acoustic signal is emitted.
  • Page 6: Dimensions (Mm)

    DIMENSIONS (MM) 26,5 300-560 26,5 26.5 ARCHIVIO CAD: \Progetti\..\ ARCHIVIO CAD: \Progetti\..\ Indoor Outdoor...
  • Page 7 RECESSED CABLE ENTRY H03VV-F ; H05VV-F 2 X 0.5 ÷ 1.5 mm...
  • Page 9 SURFACE CABLE (for one unit wiring) H03VV-F ; H05VV-F 2 X 0.5 ÷ 1.5 mm...
  • Page 10 REMOTE CONTROLLER WALL MOUNTING...
  • Page 11 EXTERNAL GRILLE MAINTENANCE...
  • Page 13: Troubleshooting

    TROUBLE SHOOTING Anomaly Possible Cause Solution Batteries are dead Change the batteries No icon shown on the controller LCD Batteries are not present Check that batteries are in there display Batteries are wrongly positioned Position the batteries correctly Go closer to the unit, pointing the The unit does not execute the command Lack of communication between the unit and the remote controller controller to the recei-ver on the left side...
  • Page 14 ERP DIRECTIVE - REGULATIONS 1253/2014 - 1254/2014 Mark Homevent Model MORI HR NEXT SEC class SEC warm climates kWh/m2.a -18.1 SEC average climates kWh/m2.a -41.7 SEC cold climates kWh/m2.a Energy label Unit typology Residential - bidirectional; Type of drive Multi-speed drive Type of Heat Recovery System Heat recovery;...
  • Page 15: Disposal And Recycling

    DISPOSAL AND RECYCLING Information on disposal of units at the end of life. This product complies with EU Directive 2002/96/EC. The symbol of the crossed-out dustbin indicates that this product must be collected separately from other waste at the end of its life. The user must, therefore, dispose of the product in question at suitable electronic and electro-technical waste disposal collection centres, or else send the product back to the retailer when purchasing a new, equivalent type device.