MORI dMEV II 150HT
De-Centralised Mechanical Extract Ventilation Fans
Read this manual carefully before using the product and keep it in a
safe place for reference.
This product was constructed up to standard and in compliance with regulations
relating to electrical equipment and must be installed by technically qualified
personnel. The manufacturer assumes no responsibility for damage to persons or
property resulting from failure to observe the regulations contained in this booklet.
PRECAUTIONS FOR INSTALLATION, USE & MAINTENANCE
The device should not be used for applications other than those specified in this manual.
After removing the product from its packaging, verify its condition. In case of doubt, contact a qualified technician. Do not leave packaging
within the reach of small children or people with disabilities.
Do not touch the appliance with wet or damp hands/feet.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the
hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Do not use the product in the presence of flammable vapours, such as alcohol, insecticides, gasoline, etc.
If any abnormalities in operation are detected, disconnect the device from the mains supply and contact a qualified technician immediately. Use
original spare parts only for repairs.
The electrical system to which the device is connected must comply with regulations.
Before connecting the product to the power supply or the power outlet, ensure that:
-
the data plate (voltage and frequency) correspond to those of the electrical mains
-
the electrical power supply/socket is adequate for maximum device power. If not, contact a qualified technician.
The device should not be used as an activator for water heaters, stoves, etc., nor should it discharge into hot air/fume vent ducts deriving from
any type of combustion unit. It must expel air outside via its own special duct.
Operating temperature: 0°C up to +50°C.
The device is designed to extract typical household air only, i.e. without excessive grease, soot, chemical or corrosive agents, or flammable or
explosive mixtures.
Do not leave the device exposed to atmospheric agents (rain, sun, snow, etc.).
Do not immerse the device or its parts in water or other liquids.
Only turn off the power supply to the unit whenever a malfunction is detected or in the case of inspection, cleaning or maintenance. Prolonged
and/or repeated power interruption to the unit (any period more than 72 hours) can create a health and safety hazard, damage components and
will invalidate any warranty.
For installation an omnipolar switch should be incorporated in the fixed wiring, in accordance with the wiring regulations, to provide a full
disconnection under overvoltage category III conditions (contact opening distance equal to or greater than 3mm).
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Do not obstruct the fan or exhaust grille to ensure optimum air passage.
Ensure adequate air return into the room in compliance with existing regulations in order to ensure proper device operation.
If the environment in which the product is installed also houses a fuel-operating device (water heater, methane stove etc., that is not a "sealed
chamber" type), it is essential to ensure adequate air intake, to ensure good combustion and proper equipment operation.
Install the product so that the impeller is not accessible from the air outlet side as verified by contact with the Test Finger (test probe "B" of the
norm EN61032) in compliance with the current safety regulations.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MORI dMEV II 150HT and is the answer not in the manual?

Questions and answers

Summary of Contents for homevent MORI dMEV II 150HT

  • Page 1 Installation & Maintenance Manual MORI dMEV II 150HT De-Centralised Mechanical Extract Ventilation Fans Read this manual carefully before using the product and keep it in a safe place for reference. This product was constructed up to standard and in compliance with regulations relating to electrical equipment and must be installed by technically qualified personnel.
  • Page 2: Technical Specifications

    Attention: do not mount the product on the window without this kit. INTRODUCTION MORI dMEV II 150HT (fig. 1) is a decentralised mechanical ventilation unit designed to ensure air extraction, in small/medium sized rooms such as bathrooms, toilets and kitchens.
  • Page 3: Standard Conformity

    VERSIONS MORI dMEV II 150HT (Humidity control version) The fan comes complete with an adjustable humidity sensor and adjustable timer. The humidity threshold is adjustable from 50% to 95% Relative Humidity via a dedicated trimmer, and the timer is adjustable from 0 - 30 minutes via a dedicated trimmer (fig. 17).
  • Page 4 STANDARD CONFORMITY 2014/35/EU Low Voltage Directive (LVD) 2014/35/EU Low Voltage Directive (LVD) 2014/30/EU Electromagnetic Compatibility (EMC), in conformity with the foll 2014/30/EU Electromagnetic Compatibility (EMC), in conformity with the following STANDARD CONFORMITY standards: standards: 2014/35/EU Low Voltage Directive (LVD) Electrical Safety Electrical Safety 2014/30/EU Electromagnetic Compatibility (EMC EN60335-1(2012)+A11+A13;...
  • Page 5 SURFACE CABLE 4 x ø 5 mm H03VV-F ; H05VV-F 2 X 0,5 ÷ 1,5 mm SURFACE CABLE 4 x ø 5 mm BASE/STD 3 X 0,5 ÷ 1,5 mm H03VV-F ; H05VV-F 3 X 0,5 ÷ 1,5 mm T-HT 2 X 0,5 ÷...
  • Page 6 4 x Ø5 mm Recessed cable entry H03VV-F ; H05VV-F BASE/STD 2 X 0.5 ÷ 1.5 mm 3 X 0.5 ÷ 1.5 mm T-HT 3 X 0.5 ÷ 1.5 mm 4 X 0.5 ÷ 1 mm The ceiling mounting gasket should be sandwiched between the fan and the ceiling ensuring that it is flat against the ceiling.
  • Page 7: Maintenance & Cleaning

    MAINTENANCE / CLEANING The unit should be cleaned regularly as explained in this leaflet to maintain performance and warranty cover. Cleaning should be carried out as and when required but please note intervals between cleaning should not exceed 12 months. The installer should explain this cleaning regime to the homeowner/occupier and ask the homeowner/occupier to keep a record of the cleaning done on this leaflet as this will be required to be provided by the homeowner/occupier to claim against any product failure under warranty.
  • Page 8: Disposal And Recycling

    DISPOSAL AND RECYCLING Information on disposal of units at the end of life. This product complies with EU Directive 2002/96/EC. The symbol of the crossed-out dustbin indicates that this product must be collected separately from other waste at the end of its life. The user must, therefore, dispose of the product in question at suitable electronic and electro-technical waste disposal collection centres, or else send the product back to the retailer when purchasing a new, equivalent type device.
  • Page 9: Warranty

    ErP DIRECTIVE - REGULATIONS 1253/2014 1254/2014 Mark Homevent Model MORI dMEV II 150 HT SEC class SEC warm climates kWh/m2.a -11,1 SEC average climates kWh/m2.a -25,5 SEC cold climates kWh/m2.a -50,6 Energy label Unit typology Residential - unidirectional Type of drive...
  • Page 10 NOTES...
  • Page 11 NOTES...
  • Page 12 Tel: +44 (0) 1384 275822, Email: sales@homevent.co.uk 46 Third Avenue, Pensnett Trading Estate, Kingswinford, West Midlands, DY6 7US, UK www.homevent.co.uk MORI dMEV II 150HT. ISSUE A. 03.21...

This manual is also suitable for:

Mori dmev iiMori dmev ii tMori dmev ii ht

Table of Contents