DALGAKIRAN L-8 User Manual page 4

Control panel of rotary screw air compressors
Table of Contents

Advertisement

PARAMETRELER
KOD
AÇIKLAMA
BASINÇ KONTROLU
( 0 = TRANSMITTER, 1 = BASINÇ ŞALTERI )
BASINÇ TRANSMITTERI UST SINIRI
YUKSEK BASINÇ ALARMI
DURMA BASINCI
ÇALIŞMA BASINCI
BASINÇ TRANSMITTERI ARALIĞI
VİDA SICAKLIĞI DURDURMA DEĞERİ
VİDA SICAKLIĞI ALARM DEĞERİ
VİDA SICAKLIĞI ÖN ALARM DEĞERİ
EN DÜŞÜK ÇALIŞMA SICAKLIĞI
ISI PROBU OFFSETİ
YILDIZ ÇALIŞMA SÜRESİ
YILDIZ ÜÇGEN ARA ZAMANI
YÜKE GEÇME GECİKME ZAMANI
BOŞTA BEKLEME ZAMANI
DEĞİŞKEN BOŞTA BEKLEME ZAMAIN
STOPTA DURMA ZAMANI
HAVA FİLTRE DEĞİŞİM ZAMANI
YAĞ FİLTRE DEĞİŞİM ZAMANI
SEPARATÖR DEĞİŞİM ZAMANI
YAĞ DEĞİŞİM ZAMANI
KOMPRESOR KONTROLÜ
BIR SAATTEKİ MAX. MOTOR KALKIŞ SAYISI
DÜŞÜK ENERJİ KAYNAĞI
RL5 SET DEĞERİ
FAN ÇALIŞMA SICAKLIĞI (RL5)
FAN KAPANMA SICAKLIK FARKI (RL5)
DİKKAT : SERVİS SÜRELERİ (P18-P22) GERİYE DOĞRU SAYAR. SET EDİLEN SÜRE DOLUNCA EKRANDA – (EKSİ) DEĞERLER
GÖRÜNÜR. (-30, SERVİS SÜRESİNİN 30 SAAT GECİKTİĞİNİ GÖSTERİR)
SET DEĞERİ
0
15 Bar
8,8 – 11 – 14,3 Bar
7,5 – 10 – 13 Bar
6,5 – 9 – 12 Bar
0
110 °C
105 °C
100 °C
0 °C
0 °C
5 sn.
50 msn.
2 sn.
2 dak.
0
30 sn.
2000 saat
2000 saat
4000 saat
2000 saat
2000 saat
6
1
0
85 °C
10 °C
3