Fault
Condensation in the
condensation tank
even though the water
drain hose is connec-
ted.
The programme does
not start.
The length of the pro-
gramme changes dur-
ing the drying cycle.
Pumping noise.
Buzzing noise.
The drying time is too
long.
Cause and troubleshooting
Ensure that the water drain hose is connected cor-
▶
rectly.
→ "Connecting the water drain hose", Page 14
Childproof lock is activated.
→ "Deactivating the childproof lock", Page 33
▶
You have not pressed inicio pausa+carga.
Press inicio pausa+carga.
▶
No programme set.
→ "Setting a programme", Page 29.
1.
→ "Starting the programme", Page 30.
2.
The programme operation is optimised electronically.
This may change the programme duration.
Not a fault – no action required.
▶
Condensation pump active.
Not a fault – normal operating noise.
▶
Compressor ventilation active.
Not a fault – normal operating noise.
▶
Fluff filter is soiled.
→ "Cleaning the fluff filter", Page 30
▶
The ambient temperature is greater than 30 °C.
Ensure that the ambient temperature is lower than
▶
30 °C.
The ambient temperature is lower than 15 °C.
Ensure that the ambient temperature is above 15
▶
°C.
Insufficient air circulation at the appliance's installation
location.
Ventilate the appliance's installation location.
▶
Appliance air inlet is blocked.
Ensure that the air inlet on the appliance is kept
▶
clear.
Heat exchanger is soiled.
→ "Running the basic appliance care programme
▶
on the appliance", Page 38
Troubleshooting en
47