Page 2
37 (used to mount motor assemblies) 315-9900-021 Actuator 360° Right Hand Torsion Spring FINISH: SIZE DWG. NO. 315-9900-022 Actuator 360° Left Hand Torsion Spring 9912M / 9924M / 9912S 340-0000-170 Anchor Mount Cable Tie Holder SCALE: 1:4 340-0000-204 Cable Tie, 4in SHEET 1 OF 7...
Page 3
Optional Key Switch Assembly shown Mogul Cylinder or Cylinder DATE NAME Extension 11/17/14 RLP DRAWN CHECKED Mogul Cylinder Ring: TITLE: 9912M 120VAC Length depends on Motor Lock, LH mogul cylinder FINISH: SIZE DWG. NO. 9912M-LH SCALE: 1:4 SHEET 2 OF 7...
Page 4
Mogul Cylinder Ring: Length depends on mogul cylinder Optional Key Switch Assembly shown DATE NAME Mogul Cylinder 11/17/14 RLP DRAWN or Cylinder CHECKED Extension TITLE: 9912M 120VAC Motor Lock, RH FINISH: SIZE DWG. NO. 9912M-RH SCALE: 1:4 SHEET 3 OF 7...
Page 5
REVISIONS ECN # REV. DESCRIPTION DATE APPROV. Initial Release 11/17/14 Cumulative: Hex Head motor/sol. mounting screws, add 10/27/15 313-0000-120, add 216-9900-217 for Sol. locks, etc. Added Half Cycle Part Numbers, 216-9900-205 now a part 1/25/18 of motor assemblies Mogul Cylinder or Cylinder Extension Optional Key...
Page 6
REVISIONS ECN # REV. DESCRIPTION DATE APPROV. Initial Release 11/17/14 Cumulative: Hex Head motor/sol. mounting screws, add 10/27/15 313-0000-120, add 216-9900-217 for Sol. locks, etc. Added Half Cycle Part Numbers, 216-9900-205 now a part 1/25/18 of motor assemblies Mogul Cylinder or Cylinder Extension Mogul Cylinder Ring:...
Page 7
AIRTEQ SYSTEMS www.airteqsystems.com 800-466-3007 9912M SERIES LOCK 9912M 5-15 RECOMMENDED SPARE PARTS ITEM Description Spare Parts PART NUMBER Half Cycle Motor Switches and Pigtail* 160-9900-150* 9912M Wiring Harness 160-9912M-100 Dead Latch Spring 315-9900-001 Latch Bolt Spring 315-9900-002 RLB Spring, LH Lock...
Page 8
AIRTEQ SYSTEMS www.airteqsystems.com 800-466-3007 9912S SERIES LOCK 9912S 12-27-17 RECOMMENDED SPARE PARTS ITEM Description Spare Parts PART NUMBER 9912S Wiring Harness 160-9912S-100 Dead Latch Spring 315-9900-001 Latch Bolt Spring 315-9900-002 9912S Latch Bolt Bumper Spring 315-9900-005 RLB Spring, LH Lock...
Page 9
THE NATIONAL ELECTRIC CODE (NEC). 7. GROUND LOCK CASE IN ACCORDANCE WITH ARTICLE 250 OF THE MOLEX #03-06-1032 NATIONAL ELECTRICAL CODE Pins: (3X) FEMALE .062 DIA 24-18 AWG TINNED AMP#350628-1 D.P.S. WIRING DIAGRAM 9912M 120VAC 4/9/14 MOTOR LOCK NONE EL-9912M...
Page 10
MOLEX #03-06-1032 MOTOR CAM (BLU) NATIONAL ELECTRICAL CODE MOTOR Pins: (3X) FEMALE .062 DIA 24-18 AWG OPEN @ 1/2 CYCLE (CONT DUTY) TINNED AMP#350628-1 CLOSE SWITCH LOCK D.P.S. WIRING DIAGRAM 9912M 120VAC RLHB 4/9/14 MOTOR LOCK, HALF CYCLE NONE EL-9912M-HC...
Page 13
REVISIONS DESCRIPTION DRAWN MOLEX #03-09-1064 Pins: (5X) FEMALE .093 DIA MOLEX #03-09-2062 Pins: (5X) MALE .093 DIA FIELD SIDE WIRING PIGTAIL (PUR) LOCK STATUS SWITCH COMMON (PIN 6) MOLEX #19-09-2029 (YEL) LOCK STATUS SWITCH N/O (PIN 2) Pins: (2X) MALE .093 DIA (RED) LOCK STATUS SWITCH N/C (PIN 5)
Page 15
9912 SERIES LOCK MAINTENANCE INFORMATION...
1. Each lock is well lubricated at the time of assembly. However, all lubricants deteriorate eventually and need replacing on a regularly scheduled basis to prevent equipment failure. Airteq Systems recommends cleaning and lubricating each type of lock according to the following instructions approximately every (2) years. (Yearly for locks in high use areas, every 3 to 6 months for exterior locations).
Page 17
3. Motor or Solenoid Position i. Verify when motor or solenoid activate that latch bolt pulls back completely a. Adjust Motor/Solenoid position down if latch bolt doesn’t pull back far enough ii. Verify when motor or solenoid returns to locked position that the latch bolt is completely out, and the actuator can rotate into the deadlock position a.
TROUBLESHOOTING If the lock is not working properly, the following chart may be used as a guide to locate and correct the problem. Because the lock receives its power from the electronic control systems, a thorough check of the control system should be conducted. Using a volt/ohm meter know to be accurate, verify the correct power inputs at the appropriate connector pin(s).