10. Troubleshooting

Fault
The compressor
does not start.
The compressor
starts but there
is no pressure.
The compres-
sor starts but
the tools do not
start.
11. Maintenance & Cleaning
m Important!
Pull out the power plug before doing any cleaning and maintenance work on the
equipment. Risk of injury from electric shock!
m Important!
Wait until the equipment has cooled down completely! Risk of burns!
18
 support@scheppach.com.au
MODEL: AIR FORCE PRODUCT CODE: 56102 02/2018
Possible cause
• No supply voltage.
• Insufficient supply
voltage.
• Outside temperature is
too low.
• Motor is overheated.
• The seals are dam-
aged.
• The hose connections
have a leak.
• A quick-lock coupling
has a leak.
Remedy
• Check the supply voltage, the
power plug and the socket-outlet.
• Make sure that the extension cable
is not too long. Use an extension
cable with large enough wires.
• Never operate with an outside
temperature of below +5° C.
• Allow the motor to cool down. If
necessary, remedy the cause of the
overheating.
• Check the seals and have any
damaged seals replaced by a
service center.
• Check the compressed air hose
and tools and replace if necessary.
• Check the quick-lock coupling and
replace if necessary.