Electrical Connection - Fisher & Paykel RDV3366N Installation Manual

Professional range
Hide thumbs Also See for RDV3366N:
Table of Contents

Advertisement

All models
IMPORTANT!
This range must be connected to the mains power supply only by a suitably
z
qualified person.
This range must be earthed.
z
Always disconnect electric supply cord from the wall outlet or service disconnect
z
before servicing this appliance.
Observe all governing codes and ordinances when grounding, in absence of which,
z
observe National Electrical Code ANSI / NFPA No. 70.
The rating label is
located under the
control panel
Wiring diagrams are
also in the service
summary, attached
to the inside of the
toe kick panel

ELECTRICAL CONNECTION

RDV3 models
A neutral supply wire must be provided from the power source (breaker panel)
z
because critical range components, including the surface burner spark reignition module,
require 120/240 VAC to operate safely and properly.
If the correct power supply circuit is not provided, it is the responsibility and
z
obligation of the installer and user to have proper power supply connected.
This must be accomplished in accordance with all applicable local codes and ordinances
by a qualified electrician. It is the responsibility of the installer to ensure compliance
of local codes. In the absence of local codes and ordinances, the power supply
connection shall be in accordance with the National Electric Code.
Observe all governing codes and ordinances when grounding. In the absence of these
z
codes or ordinances observe National Electrical Code ANSI/NFPA No. 70 current issue.
See the following information in this section for grounding method..
The ranges are to be connected to a 240/208 VAC power supply.
z
IMPORTANT!
An improper 120/240 VAC power supply will cause malfunction, damage to this
z
appliance, and possibly create a condition of shock hazard.
Improper connection of aluminium house wiring can result in a fire or shock hazard.
z
Use only connectors designed and certified for connecting to aluminium wire.
MODEL
RDV3-304
A wiring
diagram label
RIV3-304
is attached to
the back of
RDV3-366
the range
RIV3-365
RDV3-488
RDV3-485GD
RHV3-484
IMPORTANT!
The fourth prong (round grounding pin) should not, under any circumstances,
be cut or removed.
MAX.
CIRCUIT
FREQUENCY
CURRENT DRAW
27 A
30 A
57 A
50 A
29 A
30 A
72 A
50 A
44 A
50 A
44 A
50 A
75 A
50 A
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz