Fisher & Paykel RIV3 Installation Manual page 10

Hide thumbs Also See for RIV3:
Table of Contents

Advertisement

WALL SURFACE
Non-combustible
Combustible
RANGE
LOW BACKGUARD
30" models
36" models
48" models
Installations against non-combustible surfaces: you may install the range without a backguard or choose any of the three backguards.
z
Installations close to combustible surfaces (above the cooking surface): without a backguard, there must be a min. 6" (152mm) clearance.
z
Installations immediately against combustible surfaces (above the cooking surface): you must purchase and fit the Wall Mount High
z
Backguard High Shelf and Angled Vent Trim.
Non-combustible surfaces: as defined in 'National Fuel Gas Code' (ANSI Z223.1, Current Edition). Clearances from non-combustible materials
z
are not part of the ANSI Z21.1 scope and are not certified by UL. Clearances of less than 6" (152mm) must be approved by the local codes
and/or by the local authority having jurisdiction.
10
BACKGUARD CONSIDERATIONS
NO BACKGUARD
min. 6"
(152mm)
NO BACKGUARD
RANGE MOUNT
HIGH BACKGUARD, LOW SHELF
BGRV2-1230
BGRV2-1236
BGRV2-1248
BACKGUARD OPTIONS
min. 30"
(762mm)
min. 1/2"
(13mm)
CUSTOM BACKGUARD
made from non-combustible materials
HIGH THICK BACKGUARD WITH ANGLED TRIM
BGRV2-3030H, BGRV2-3036H, BGRV2-3048H
WALL MOUNT
HIGH BACKGUARD, HIGH SHELF
BGRV2-3030
BGRV2-3036
BGRV2-3048
LOW THIN BACKGUARD
BGRV2-1230, BGRV2-1236, BGRV2-1248
BGRV2-3030, BGRV2-3036, BGRV2-3048
WALL MOUNT
INCHES
BGRV3-3030H
29 7/8
BGRV3-3036H
35 7/8
BGRV3-3048H
47 7/8
Note: Backguards can be purchased separately.
All ranges come fitted with an Integral Vent
Trim only.
For more information on Backguard
installation, refer to the separate instructions
provided with your backguard. Backguard
Installation Instructions can also be
downloaded from our website, www.
fisherpaykel.com
HIGH THIN BACKGUARD
BACKGUARD WIDTH
MM
759
911
1216

Advertisement

Table of Contents
loading

Table of Contents