HODAKA HT-1200N Operating Manual

HODAKA HT-1200N Operating Manual

Flue gas analyzer

Advertisement

Quick Links

Flue gas analyzer HT-1200N
Operating Manual
HODAKA CO,. LTD.
1-6-17 Takadono, Asahi-ku, Osaka 533-31 Japan
tel +81-6-6922-5501 fax +81-6-6922-5895
e ‐ mail ; info@hodaka-inc.co.jp
UPL ; http://www.hodaka-inc.co.jp
ver.130101

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HT-1200N and is the answer not in the manual?

Questions and answers

Summary of Contents for HODAKA HT-1200N

  • Page 1 Flue gas analyzer HT-1200N Operating Manual HODAKA CO,. LTD. 1-6-17 Takadono, Asahi-ku, Osaka 533-31 Japan tel +81-6-6922-5501 fax +81-6-6922-5895 e ‐ mail ; info@hodaka-inc.co.jp UPL ; http://www.hodaka-inc.co.jp ver.130101...
  • Page 2: Table Of Contents

    Not observing can mean loss of warranty claims. 5.2 Interface RS 232 3.1 Safety Instruction The device HT-1200N is only to be used for its indicated purpose: ● 6. Operating The measurement of flue gases, of combustion air and gas temperature.
  • Page 3: Device Illustrations

    1. HT-internal battery(standard scope of supply) Probe Display 2. HT-battery charge (standard scope of supply) 100V / 12 Vdc / 100mA Measurements from line power : Use the HT-1200N only with the HT power supply 100v / 12Vdc / 100mA 5.1 Prepare measurement Metal cone The HT-battery charger can be connected to the HT-1200N.
  • Page 4: Operating

    6.2 Gas measurement 6.Operating Gas measurement 6.1 Switch ON the unit View last values By pressing the -key the HT-1200N will be switched ON. Zero setting Extension menu Programtype: :Select the program type HODAKA Program1 HT-1200N :Confirmation of the selection...
  • Page 5: Last Values

    :Input soot number in 1 steps Soot 1: P :Print-out :Line transfer Soot 2: Print :Strage (in line 1):Back to input T-Boiler Soot 3: Store oily negative Abort :Back to main menu (in line 4):Storage The last selected strage space is selected. Print :Print-out Store...
  • Page 6: Measurement Ht-1200N To Pc

    : memory is deleted Total : The storage places marked with * are occupied Cust. 1 * :Select customer 6.5.1.3 Measurement HT-1200N to PC Cust. 2 :Activate storage place Cust. 3 View stored data :Select the function Cust. 4...
  • Page 7: Date/ Time

    7.Calculation basis 6.5.2.1 Date / Time 7.1 Analysis and calculation :The time stored in the HT-1200N and Date Time the date is displayed. 13.01.06 10:51:10 Calculated measuring items Unit Unit Continuously measured items [%] [%] [%] [℃] Temperature (Kthermocouple) *...
  • Page 8: Technical Specifications

    0~650℃ HT-1379D International transportation cost is not include in guarantee. Probe handle HODAKA CO., LTD shall not be liable for any loss or damage whatever arising with hose/condensate trap Probe handle HT-7201G from content errors or any mis-use of this instrument.