General Instructions
Overlap
Shiplap
Cladding
Cladding
01GRO0606-V1
6x6 Groundsman Shed Double Doors Opening Window
01GRO0705-V1
7x5 Groundsman Shed Single Door Opening Window
01GRO0806DD-V1
8x6 Groundsman Shed Double Doors Opening Window
01GRO1006DD-V1
10x6 Groundsman Shed Double Doors Opening Windows
01GRO1008DD-V1
10x8 Groundsman Shed Double Doors Opening Windows
01GRO1208DD-V1
12x8 Groundsman Shed Double Doors Opening Windows
Refer to the instructions pages for your speci c product code
Fixed
Opening
Windows
Windows
Please retain product label and instructions for future reference
N/A
No
Solid Sheet
Floor
Windows
BEFORE YOU START PLEASE READ INSTRUCTIONS CAREFULLY
- Check the pack and make sure you have all the parts listed.
- When you are ready to start, make sure you have the right tools at hand
(not supplied) including a Phillips screwdriver, Stanley knife, wood saw,
step ladder and drill with 2mm bit.
- Ensure there is plenty of space and a clean dry area for assembly.
The images used throughout the instruction manual are generic and for
illustration purposes only; they may vary dependant on your actual product. It is
strongly advised they are read and understood before attempting installation.
TIMBER
As with all natural materials, timber can be a ected during various weather
conditions. For the duration of heavy or extended periods of rain, swelling of the
wood panels may occur. Warping of the wood may also occur during excessive
dry spells due to an interior moisture loss. Unfortunately, these processes cannot
be avoided but can be helped. It is suggested that the outdoor building is
sprayed with water during extended periods of warm sunshine and sheltered as
much as possible during rain or snow.
Our buildings are coated with a water based high quality colorant; this only
helps to protect the product during transit and for up to 3 months against
mould. To validate your guarantee and ensure longevity of the product, it is
ESSENTIAL the building is treated with a wood preserver within the rst three
months of assembly and thereafter in accordance with the manufactures
recommendations. Care must be taken to ensure the product is placed on a
suitable base
BUILDING A BASE
When thinking about where the building and base is going to be constructed:
Ensure that there will be access to all sides for maintenance work and annual
treatment.
Ensure the base is level and is built on rm ground, to prevent distortion. Refer
to diagrams for the base dimensions, The base should be slightly smaller than
the external measurement of the building, i.e. The cladding should overlap the
base, creating a run o for water. It is also recommended that the oor be at
least 25mm above the surrounding ground level to avoid ooding.
TYPES OF BASE
- Concrete 75mm laid on top of 75mm hard-core.
- Slabs laid on 50mm of sharp sand.
Whilst all products manufactured are made to the highest standards of Safety and in the case of childrens products
independently tested to EN71 level, we cannot accept responsibility for your safety whilst erecting or using this product.
Mercia Garden Products Limited, Sutton On Trent, Newark, Nottinghamshire, NG23 6QN
T&G Floor
Solid Sheet
Roof
x2
All building's should be erected by two
adults
For ease of assembly, it is advisable to
pilot drill all screw holes and ensure
all screw heads are countersunk.
2mm Drill bit
Winter = High Moisture = Expansion
Summer = Low Moisture = Contraction
CAUTION
Every e ort has been made during the
manufacturing process to eliminate the
prospect of splinters on rough surfaces
of the timber. You are strongly advised
to wear gloves when working with or
handling rough sawn timer.
For Assistance Please
Contact Customer Care on
01636 880514
www.merciagardenproducts.co.uk
T&G Roof
P 1

Advertisement

loading

Summary of Contents for Waltons 01GRO0606-V1

  • Page 1 BEFORE YOU START PLEASE READ INSTRUCTIONS CAREFULLY All building’s should be erected by two - Check the pack and make sure you have all the parts listed. 01GRO0606-V1 adults - When you are ready to start, make sure you have the right tools at hand...
  • Page 2 01GRO1006DD-V1 Please retain product label and instructions for future reference Fixing Kit Overall Dimensions: Length = 3099mm Width = 1914mm Height = 2110mm Ridge Bar - 40x60x2918mm Base Dimensions: Length = 2997mm Width = 1783mm Ridge Support - 27x70x898mm Qty 2 Before assembly please make sure you have a suitable base ready to erect your...
  • Page 3 Please retain product label and instructions for future reference Step 2 Nail Bag 50mm Screw x 22 Fix the T-hinges onto the 40mm Screw x 12 doors and door frame as shown. using 30mm 30mm Screw x 128 screws. Ensure that each hinge is fixed to the doors 20mm Screw x 12 going through to the...
  • Page 4 Please retain product label and instructions for future reference Step 4 Step 6 Fix the corners with 3x For buildings with no windows Place the floor on a firm and 50mm screws as shown in level base, ensure base has fix a plain panel here.
  • Page 5 Please retain product label and instructions for future reference Step 8 Step 9 Fix the roof panels on either Cut the felt into three side of the gables as shown sheets measuring 3199mm. in the diagram. Ensure the Lay them onto the building roof framing fits into the as shown in the diagram slots at the top of both...
  • Page 6 Please retain product label and instructions for future reference Step 10 Step 12 Fit the cover trims to the front *SCREW COUNT PER WINDOW and back of the building as shown in the illustration using 30mm screws. Place the window strip 11mm above Trim the length of the cover the window gap in the window panel 30mm...
  • Page 7 Please retain product label and instructions for future reference Step 13 Step 14 Rim lock fixing Attach the tower bolt Rim lock mounting block to the top Fig 1. (internal view) of the slave door with Place the lock onto internal 2x30mm screws.

This manual is also suitable for:

01gro0705-v101gro0806dd-v101gro1006dd-v101gro1008dd-v101gro1208dd-v1