After dive

1. Switch off the heating before you put off diving equipment, disconnect E/O
cord.
2. After unzipping your dry suit, disconnect the cable from heating vest and
heating gloves before you put off the dry suit.
3. Rinse battery pack canister and E/O connectors with fresh clear water.
4. Before opening canister cover make sure it is dry.
5. Disconnect power supply removing canister cover. Check if o-ring, E/O
cord, toggle switch rubber hood (H series only) are not damaged.
6. Check flood symptoms by shaking the canister cover and listening for
squelch sound. In case of cover flooding, unscrew the cable sealing gland,
remove the cable with care and spill out the water.
7. Wipe to dry the o-ring and surface of the canister edge, removing sand
and dirt. Do not grease the o-ring.
8. Do not transport the battery pack canister when its cover remains in
connected position. When not is use, the cover should be replaced in half-
turn, with banana connectors in blind plugs. Using of transport cases and
E/O protective caps (TERM) is advised to avoid damages during transport.

Warranty

1. Two years warranty from a day of purchase is given for all products of
Yellow Diving. The warranty on Light and Heating modules relates to their
performance with the exception of the battery packages, cables,
connectors E/O, light bulbs, electronics, heating gloves, rubber hood
switch for which the warranty period is 12 months from a date of
purchase.
2. Floods, leaks, punctures, and broken bulbs, etc., are not covered by the
warranty unless they are the direct result of a material or workmanship
defect.
3. Warranty does not cover damages caused by improper use, mechanical
damages, wrong maintenance, repairs and modifications performed
outside Yellow Diving service department. Natural process of wearing-out
of the elements of the system is not covered either.
4. Normal evidences of usage, small scratches, scrapes, are not warranty
covered.
5. Warranty claims are accepted and free-of-charge service is performed only
if original proof of purchase and signed and stamped warranty card is
presented with matching serial number.
6. The cost of shipping to Yellow Diving service department is on the client
side.
We are real fans of diving and we dive ourselves as well. Therefore you can
count on us in case of any tiny repairs, not necessary from manufacturer fault.
If any problems, questions or doubts please contact local dealer
Yellow Diving heating system manual
This kind of service we provide for life.
or directly the producer.
Yellow Diving
ul. 11 Płk. Piechoty 30
78-500 Drawsko Pomorskie
Poland