Printer Initialization - 4BARCODE Technology 4B-2044A Series User Manual

Direct thermal barcode printer
Table of Contents

Advertisement

4.3 Printer Initialization

Printer initialization is used to clear DRAM and restore printer settings to defaults. The
only one exception is ribbon sensitivity, which will note be restored to default.
Printer initialization is activated by the following procedures.
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns blue after 5 blue blinks. (Any blue will do
during the 5 blinks).
The LED color will be changed as following:
Blue red (5 blinks)  purple(5 blinks) blue (5 blinks) solid blue
Printer configuration will be restore to defaults as below after initialization.
Parameter
Speed
Density
Label Width
Label Height
Media Sensor Type
Gap Setting
Print Direction
Reference Point
Offset
Tear Mode
Peel off Mode
Cutter Mode
Serial Port Settings
Code Page
Country Code
Clear Flash Memory No
IP Address
Note:
Always do gap/black mark sensor calibration
Default setting
127 mm/sec (5 ips)
8
4" (101.6 mm)
7.08" (180 mm)
Gap sensor
0.157" (4.0 mm)
0
0,0 (upper left corner)
0
On
Off
Off
9600 bps, none parity, 8 data bits, 1 stop bit
850
001
DHCP
after printer initialization.