SIAP+MICROS e015a DA15K User Manual

SIAP+MICROS e015a DA15K User Manual

Data acquisition systems

Advertisement

Quick Links

e015a DA15K
e015b DA15KE
Data Acquisition Systems
User Guide
SIAP+MICROS S.r.l.
tel +39 0438 491411 – fax +39 0438 401573
Via del Lavoro,1
31020 – Castello Roganzuolo di San Fior (TV) - ITALY
email info@siapmicros.com
di San Fior (TV)
www.siapmicros.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the e015a DA15K and is the answer not in the manual?

Questions and answers

Summary of Contents for SIAP+MICROS e015a DA15K

  • Page 1 DA15K e015b DA15KE Data Acquisition Systems User Guide SIAP+MICROS S.r.l. tel +39 0438 491411 – fax +39 0438 401573 Via del Lavoro,1 31020 – Castello Roganzuolo di San Fior (TV) - ITALY email info@siapmicros.com di San Fior (TV) www.siapmicros.com...
  • Page 2: Table Of Contents

    DA15K e015b DA15KE INDEX Precautions and safety measures ......................1 1.1 Intended use ............................2 1.2 Warnings ............................... 2 1.3 Moving ..............................3 1.4 Unpacking ............................. 3 1.5 Safety procedure to turn on DA15K data logger .................. 3 1.6 During operation ........................... 3 1.7 Storage ..............................
  • Page 3: Precautions And Safety Measures

    Substitution of components and intervention inside should be performed only by qualified and instructed service personnel, after disconnecting the main power supply. Pay attention to any warning label on order to avoid potentially dangerous procedures. User guide (v.02) pag.1 Printed in e015-di DA15K [Eng].docx Siap+Micros S.r.l.
  • Page 4: Intended Use

    Substitution of components and intervention inside should be performed only by qualified and instructed service personnel, after disconnecting the main power supply. Pay attention to any warning label on order to avoid potentially dangerous procedures. User guide (v.02) pag.2 Printed in e015-di DA15K [Eng].docx Siap+Micros S.r.l.
  • Page 5: Moving

    6. Turn on the external power supply. 1.6 During operation During operation, please avoid to alter the electrical connections related to analog and digital inputs; also avoid to alter the connections of the power supplies. User guide (v.02) pag.3 Printed in e015-di DA15K [Eng].docx Siap+Micros S.r.l.
  • Page 6: Storage

    All line protections, both for short and for surges or lightning are self-restoring (PTC, self restoring fuses, ESD protections and so on). The product does not have removable/replaceable line protection. 1.9 Description of case and connections 1.9.1 Box of data processing electronics Installation and Dimensions User guide (v.02) pag.4 Printed in e015-di DA15K [Eng].docx Siap+Micros S.r.l.
  • Page 7 Three pins for the CAN – BUS port, for connecting devices with CAN – BUS. Three pins for the SDI – 12 port for connecting devices with SDI – 12 protocol User guide (v.02) pag.5 Printed in e015-di DA15K [Eng].docx Siap+Micros S.r.l.
  • Page 8 TX and RX COM3 status of the lines of transmission and reception of serial 3 TX and RX COM2 status of the lines of transmission and reception of serial 2 User guide (v.02) pag.6 Printed in e015-di DA15K [Eng].docx Siap+Micros S.r.l.
  • Page 9: Box Of Data Acquisition Electronics

    DA15Kx 1.9.2 Box of data acquisition electronics Dimensions Installation Panel or wall mount with M3 screw Panel or wall mount with low profile DIN rail support User guide (v.02) pag.7 Printed in e015-di DA15K [Eng].docx Siap+Micros S.r.l.
  • Page 10 DIG IN B : Optoisolated digital input (see picture at the top page ) DIG IN C : Optoisolated digital input • Logic level • Sinusoidal Input (IF11-IF12) • Frequency • Sinusoidal Input (IF7-IF8) • Counter • Standard 12V sensor User guide (v.02) pag.8 Printed in e015-di DA15K [Eng].docx Siap+Micros S.r.l.
  • Page 11: Configurable 4 - 20Ma Analog Input Channels

    1.11 Description of directories and files DA15K data logger is equipped with Windows CE 6.0 operating system and it is factory configured with the following structure of drives, directories and files: User guide (v.02) pag.9 Printed in e015-di DA15K [Eng].docx Siap+Micros S.r.l.
  • Page 12: Drives

    All software contained in this directory or with a link in this directory are automatically started at the power on of the data logger. User guide (v.02) pag.10 Printed in e015-di DA15K [Eng].docx Siap+Micros S.r.l.
  • Page 13: Using Da15K Data Logger

    Voltage detected (1 flash empty, 5 flashes full). Few seconds later turning on the display, bootstrap mask with label “SIAP+MICROS” will appear. 30s later, Windows CE 6.0 O.S. will start to run and the applications placed in the directory “\NandFlash\Windows\StartUp”...
  • Page 14: Tabs Of Data Logging Software

    USB interface. At the end, save the changes using the "Save”. 2.2.3 Status Displays the status of the file archives with the occupied and free size for any file. User guide (v.02) pag.12 Printed in e015-di DA15K [Eng].docx Siap+Micros S.r.l.
  • Page 15: Setting

    • alarms • The steps to restart the program • The error was detected in clock synchronization • The errors in connection with the communication devices. User guide (v.02) pag.13 Printed in e015-di DA15K [Eng].docx Siap+Micros S.r.l.
  • Page 16: Procedure For Substitution Of Data Logger Software

    "Hard Disk", copy the new program, navigate to the directory "\ NandFlash \ DA9000" and overwrite the file listed. After performing the copy, start the START.EXE software or restart the datalogger. User guide (v.02) pag.14 Printed in e015-di DA15K [Eng].docx Siap+Micros S.r.l.
  • Page 17: Acquisition Cycle

    SD memory card can be removed in every moment, even if the software is running. In order to avoid truncation of the stored records, it’s highly recommended to close the program or turn off the DA15K data logger during replacement. User guide (v.02) pag.15 Printed in e015-di DA15K [Eng].docx Siap+Micros S.r.l.
  • Page 18: Data Format

    In detail the four types are: • Record track for Statistical Data • Record track for Instantaneous data • Record track for Alarm Data • Record track for Calibration Data User guide (v.02) pag.16 Printed in e015-di DA15K [Eng].docx Siap+Micros S.r.l.
  • Page 19: Regulations

    Material in respect of radio interference; User guide (v.02) pag.17 Printed in e015-di DA15K [Eng].docx Siap+Micros S.r.l.
  • Page 20: Emc

    … Omissis” 4.2 EMC This equipment has been designed in accordance with the requirements of the Directives listed in the EC declaration attached to the product. User guide (v.02) pag.18 Printed in e015-di DA15K [Eng].docx Siap+Micros S.r.l.
  • Page 21: Operating Conditions

    The manufacturer may update the product described in this document, or parts of it, at any time without notice. • It is not allowed reproduce or duplicate, entirely or part of this document without the permission of SIAP+MICROS srl. User guide (v.02) pag.19...
  • Page 22: Quick Guide

    DA15Kx 6 Quick Guide Set clock without DAK 1. Close DA9000 program pressing X button; confirm typing YES and then OK User guide (v.02) pag.20 Printed in e015-di DA15K [Eng].docx Siap+Micros S.r.l.
  • Page 23 DA15Kx 2. Open folder 3. Open Nand Flash Folder 4. Open DA9000 Folder User guide (v.02) pag.21 Printed in e015-di DA15K [Eng].docx Siap+Micros S.r.l.
  • Page 24 DA15Kx 5. Start RTC program 6. Set clock and date and press WRITE 7. Switch OFF and switch ON the datalogger User guide (v.02) pag.22 Printed in e015-di DA15K [Eng].docx Siap+Micros S.r.l.
  • Page 25: Changing Configuration Without Dak

    DA15Kx 6.2 Changing configuration without DAK 1. Close DA9000 program. pressing X botton, confirm with YES and OK User guide (v.02) pag.23 Printed in e015-di DA15K [Eng].docx Siap+Micros S.r.l.
  • Page 26 3. Insert the Usb pen drive and wait few seconds for its loading. Then open “Hard disk” folder 4. Select "CNF" configuration file and, if present, "INI" settings file and Copy them. User guide (v.02) pag.24 Printed in e015-di DA15K [Eng].docx Siap+Micros S.r.l.
  • Page 27 DA15Kx 5. Open Nand Flash Folder 6. Open DA9000 Folder User guide (v.02) pag.25 Printed in e015-di DA15K [Eng].docx Siap+Micros S.r.l.
  • Page 28 DA15Kx 7. Paste new file in the DA9000 folder and confirm update with "Yes to All" 8. Remove USB pen drive and Switch OFF and switch ON the datalogger User guide (v.02) pag.26 Printed in e015-di DA15K [Eng].docx Siap+Micros S.r.l.

This manual is also suitable for:

E015b da15ke

Table of Contents