Pre-Treatment machine operating instructions
Attention:
As the treatment solution is a kind of slightly viscous liquid (especially the treatment solution
with dark color T shirt), it will increase the viscosity when exposed to the air for more than an
hour, which makes it easy to block the nozzle. Therefore, it is recommended to clean the
nozzle as soon as possible after using the spray machine, generally not within 12 hours
Chapter iii maintenance and maintenance
Daily maintenance
In order to ensure the normal operation of sprinkler, daily maintenance is very important, as detailed
below:
1: Since there is air in the liquid pump, the pumping force will be relatively small, so when the
treatment liquid is used up and the treatment liquid is not added in time, a large amount of air will
enter the pipeline. At this point, long press the cleaning button, so that the liquid pump will continue
to work until the liquid erupts evenly from the nozzle)
2: The nozzle should be cleaned timely. If the nozzle is blocked and cannot be sprayed or sprayed
unevenly, the nozzle can be removed and the nozzle can be soaked in a cup for 24 hours. Then the
nozzle can be cleaned gently with a soft toothbrush
3: Since the treatment solution is acidic and prone to rust, it is necessary to regularly apply butter
or lubricating oil to moving metal parts such as linear guide rails