Fisher & Paykel DCS RF24BTL1 Installation, Operation And Maintenance Instructions page 12

Outdoor beer dispensers
Table of Contents

Advertisement

Available languages

Available languages

US
CA
Rear of counter top
Diameter
to suit
counter
top depth
" (6 mm)
1
4
25
"
5
16
radii,
(64.3 cm)
typical
CAUTION
!
The cutout dimensions shown in Figure 23 are based on
a 25
" (64.3 cm) deep counter top. Your counter top may
5
16
be different than this and require other front to back dimen-
sioning. Refer to the product dimensions on page 8 when
determining the required dimensions.
Grate from top of
beer dispenser
Counter top
sump from
literature pack
Figure 24
USING YOUR BEER DISPENSER
1
"
3
8
(3.5 cm)
1
" (38 mm)
1
2
typical
Diameter
2
7
38
(7.3 cm)
(10.8 cm)
6
6
"
1
8
(16.2 cm)
(15.6 cm)
12
"
1
4
(31.1 cm)
Figure 23
Tower
4. If you are installing your keg refrigerator under a
counter you will need to drill 5 holes in the counter top
to mount the tower. The first hole is a 1
hole located at the center of the tower for the beer
line, locate approximately 13
front edge of the counter top (based on a counter top
"
depth of 25
per the dimensions in Figure 23. The hole diameter
is dependent on the counter top material and if screw
anchors are required. The screws supplied are in the
4
"
1
4
literature pack and are a #10 x 1" type AB stainless
steel screw. Mark and cut the rectangular cutout for
the drain sump. After the holes are drilled and the
"
3
8
keg refrigerator is in place under the counter top feed
the beer line through the tower gasket, the 1
in the counter top and the hole in the top of the keg
refrigerator. Mount the tower to the counter top with the
4 screws provided. Place the counter top drain sump,
from the literature pack, in the rectangular hole with the
radius cutout to the rear around the tower and place
the grate in the sump.
5. Mount the regulator to the CO
use the new plastic washer you received from the gas
supply company. Note that the regulator has left hand
threads and has to be turned counterclockwise to
tighten. Tighten with the adjustable wrench or the 1
open end wrench.
6. Connect the red air line(s) from the regulator to the
large air line fitting on the keg coupler with a large
hose clamp (connection
7. Connect the clear beer line from the tower to the small
air line fitting on the keg coupler with a small hose
clamp (connection
12
" (34.3 cm) from the
1
2
"). Next drill the 4 tower mounting holes
5
16
tank (connection
2
).
C
).
A
Figure 25
" diameter
1
2
" hole
1
2
)
B
"
1
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcs rf24btr1Dcs rf24tr1Dcs rf24tl1

Table of Contents