Note: The Bin Switch will only shut down the unit at the end of a harvest or within the first
5 minutes of the freeze cycle. To shut the unit down outside of this time period
turn the control switch to "OFF".
8) Replace the Bin Control Cover.
9) Move the Control Switch to the "Service" position. Then move the Service Switch to
the "Drain" position.
10) Replace the Front Panel.
11) Turn on the power supply for 2 minutes to allow the icemaker to drain.
12) Turn off the power supply and remove the Front Panel.
13) Move the Control Switch, on the Control Box, to the "ICE" position.
14) Replace the Front Panel and turn on the power supply.