Error Display - Marantz SR7013 Service Manual

Hide thumbs Also See for SR7013:
Table of Contents

Advertisement

1.4. Error display

See the table below for descriptions of the displayed errors and countermeasures for these.
If multiple errors occur, only one item is displayed.
The priority order is w, e, r, t, y, q.
Condition
The model name, brand name and region information written in the firmware are compared
to the region settings in the PCB. This error is displayed if the information does not match.
q
Firm Check
NG
" ▲ " is displayed as the first character if the firmware is not correct (see the illustrations on
the right).
An error occurs in Loop back Test of the DDR memory which is performed during the initial
setting of i/p Scaler(ADV8003).
w
IP SCALER NG
During the initial setting of i/p Scaler ( ADV8003 ) , there is not the reply of the Loop back Test
result of the DDR memory .
If the Main CPU version is not supported by the GUI Serial Flash (ADV8003),
e
GUI Serial
" ▼ " is displayed as the first character of the GUI firmware version.
Flash NG
If GUI Serial Flash is damaged, " ▲ " is displayed as the first character.
r
This error is displayed if there is no response from the DIR.
DIR NG
Boot error 1 (After reset the DSP, DSP_Flag0 port is "Low")
Boot error 2 (After reset the DSP, DSP initialization is not completed)
(Unused)
Command error 1 (After sending the command to the DSP, DSP_Flag0 port is "Low".)
t
Command error 2 (After sending the command to the DSP, MCU received "COMMAND ER-
DSP # NG
ROR".)
( # : 1/2/3/4)
Command error 3 (After sending the command to the DSP, MCU did not receive "COMMAND
SUCCESS".)
IDL error 1 (Before receiving IDL, "COMMAND BYTE" is not cleared.)
IDL error 2 (MCU received "IDL SERIOUS ERROR".)
SPI communication error
y
Error occurred in BACKUP. it is an error of the check sum.
BACKUP NG
States
150
Display
FIRM ERROR
M:*************
•• Check the resistor for setting the region [R1590/R1589,
Main FBL :**.**
DIGITAL PCB].
DSP#
:**.**
• Write the firmware for the correct region.
Audio PLD:**.**
Video PLD:**.**
GUI
:********
• Check the circuits around the IP SCALER [IC401, DIGITAL
IP SCALER ERR 01
PCB] and DDR2 [IC402/IC403].
If there appear to be no problems, [IC401] or [IC402/IC403] is
IP SCALER ERR 02
faulty.
GUI VER. ERROR
• Check the firmware version.
GUI
:********
GUI
:********
• Check the DIR [IC202, DIGITAL PCB] and surrounding circuits.
DIR ERROR 01
DSP# ERROR 01
DSP# ERROR 02
DSP# ERROR 03
DSP# ERROR 04
• Check the DSP [IC251/IC261/IC271/IC281, DIGITAL PCB] and
DSP# ERROR 05
surrounding circuits.
DSP# ERROR 06
DSP# ERROR 07
DSP# ERROR 08
DSP# ERROR 09
BACKUP ERROR
TROUBLE SHOOTING

Advertisement