2.0 Detector Installation
2.1 Detector Installation
The detector can either be wall, corner or ceiling mounted by using a special bracket base
for the bracket mounting.
1.
2. Insert wire through the bracket and holes "A" and "B".
3. Mount the bracket base to the wall or to the ceiling with the suitable adaptor. Hold the
4. Insert the wires through the bracket and connect the wires to the terminal block.
5. Replace the cover by inserting it back in the appropriate closing pins and screw in the
5
To remove the front cover, unscrew the holding screw and gently raise the front cover.
Unscrew the
holding
screw and
open base
detector base in front of the protected area and tighten the bracket screw.
holding screw.
Wire Size Requirements
Use #22 AWG (0.5 mm) or wires with a larger diameter.
Use the following table to determine the required wire
gauge (diameter) depending on the length of wire
between the detector and the control panel.