Option menus
Off-timer function
On Screen display
Initial Input
Initial VOL. level
Maximum VOL. Level
INPUT lock
Button lock
Studio W/B
Remocon User Level
ID Select
Remote ID
Serial
Slot power
Note :
How to set Remocon User Level and Remote ID off
1. Access service mode (CAT-mode) and press SET UP key on
remote.
2. Accsess option menu.
3. Change Remocon User Level and/ or Remote ID set to Off.
13. Conductor Views
13.1. PF-Board
default setting
Enable
Off-timer operation Enable/Disable.
On
Enable/Disable to display input mode indication after
power on and no signal indication.
Off
Sets the initial input mode when the power is turned on .
Allow input mode selection while power is on.
Off
Sets the initial volume level when the power is turned on.
Allow Volume control while power is on.
Off
Sets the maximum volume to desired level. Volume cannot
exceed this level.
Off
Fixes the input mode to AV, Component/RGB or PC. Can
not change input mode by input selection key.
Off
Enable/Disable front operation buttons (Input and/or
volume up/down)
Off
Set warm mode color temperature to 3,200 Kelvin.
Off
Remote key invalidation.
Off : Valid key is all key of remote.
User1 : Valid key are only Stand-by (ON/OFF), Input,
Status, Surround, Sound mute On/Off, and volume
adjustment.
User2: Valid key is only Stand-by (ON/OFF).
User3 : All keys are null and void
0 to 100
Set ID number from 001 to 100.
Off
Remote ID function On/Off.
(While the Remote ID on, standard remote function can not
control the unit.)
Off
Serial ID function On/Off
Off
Sets the slot power mode the power is turned on.
Allow Optional Terminal Board insert Slots while power is
on.
21