The hall sensor determines the speed and direction of the motor.
It also can read that the load is off balance when the drum speed fluctuates.
Test point
- Voltage Testing Hall Sensor at Stator
and
Result
(Hall
Sensor)
If measuring voltage from the Main PCB Assembly to the Hall Sensor, use the
following steps:
1. Unplug power cord.
2. Remove rear washer panel.
3. Locate Hall sensor connector on the stator behind the rotor.
4. Place meter leads on terminals 5 to 4, white to gray.
5. Plug in power cord, close door, and press power button.
6. You should measure 10 to 15 V
DO NOT PRESS START!
white wire, and gray wire are OK! If not, follow testing output voltages on
control board in next section.
(2) (4)
(1) (3) (5)
. If 10 to 15 V
DC
DC
42
is present, control board,