Download Print this page
Silver King SKFMW34-ELUS1 Technical Manual And Replacement Parts List

Silver King SKFMW34-ELUS1 Technical Manual And Replacement Parts List

Mobile freezer

Advertisement

Quick Links

1600 Xenium Lane North, Minneapolis, MN 55441-3787
Phone (800) 382-3329
FORM NO. 45083 REV D 07/2021
Technical Manual
and
Replacement Parts List
Mobile Freezer
MODELS:
SKFMW34-ELUS1 (SHOWN)
SKFMW34-ELUS3
SKFMW34-ELUS4
Specifications Subject to Change Without Notice.
1

Advertisement

loading

Summary of Contents for Silver King SKFMW34-ELUS1

  • Page 1 Technical Manual Replacement Parts List Mobile Freezer MODELS: SKFMW34-ELUS1 (SHOWN) SKFMW34-ELUS3 SKFMW34-ELUS4 1600 Xenium Lane North, Minneapolis, MN 55441-3787 Phone (800) 382-3329 FORM NO. 45083 REV D 07/2021 Specifications Subject to Change Without Notice.
  • Page 2 UNCRATE AND INSPECT FOR DAMAGE Upon delivery of your new Silver King unit, uncrate at once to inspect for possible freight damage following the instructions printed on the exterior of the container. Report any damages to the carrier responsible for transportation and promptly present a written claim for any evidence of mishandling.
  • Page 3: Installation

    Your Silver King freezer is equipped with an eight (8) foot power cord. Any attempt to modify the plug will void the warranty, terminate the manufacturers responsibility, and could result in serious injury.
  • Page 4: Operation

    OPERATION Initial Start Up After satisfying the installation requirements, the freezer is ready to operate. The unit will start when the power cord is connected to a live electrical receptacle. If the Compressor and Condenser Fan are not running when the unit is initially connected to power, check to make sure that the Temperature Control is not set to the ‘off’...
  • Page 6: Part Description

    REPLACEMENT PARTS LIST – SKFMW34-ELUS ITEM NO PART DESCRIPTION PART NO BOTTOM COVER INSULATED 36210 TOP COVER INSULATED 36214 END PANEL LOUVERED 35920 KIT 2" CASTER 10314-25 KIT 5" CASTER 10314-75 POWER CORD 115V 36144 CORD WRAP 37173 GROMMET COMPRESSOR MOUNT 20481 WASHER COMPRESSOR MOUNT 22401...
  • Page 8 Thermistor Field Testing Use the guide below to test if a thermistor (temperature probe) is functioning properly. See the replacement parts list for part number information. Table 2 is valid for all thermistors listed on table 1.  Establish Thermistor Temperature Table 2 Check the display’s temperature reading.
  • Page 9 Silver King’s review to be inefficient or inoperative due to defects in material or factory workmanship.
  • Page 10 Equipment, that it will replace the compressor with one of similar design and capacity, exclusive of delivery and installation charges, if it is found subject to Silver King’s review to be inefficient or inoperative due to defects in material or factory workmanship. It is the original purchaser’s responsibility to return the serial plate of the defective compressor, or at Silver King’s option the complete compressor, to the factory.
  • Page 11 (Returned Merchandise Authorization) form must be completed and then approved by Silver King. Please contact Silver King for details. Restocking fee will apply. • All electrical equipment is single phase. • Prices, designs, and specifications are subject to change without notice. • Payments via credit card are subject to a 3.5% surcharge.