Summary of Contents for Tamarack Solar TTP Series

  • Page 1 Pole Mount - TTP Series Installation Manual For Models TTP-4, TTP-4HW, TTP-6, and TTP-6HW TTP-46-MAN 2022 Edition v2.3 90392 TTP-4 4 Module Top of Pole Mount 90408 TTP-4HW 4 Module High Wind Top of Pole Mount 90415 TTP-6 6 Module Top of Pole Mount...
  • Page 2: Installer Responsibilities

    Pole Mount - TTP Series Disclaimer This manual describes proper installation procedures and provides necessary standards required for product reliability. Warranty details are available on our website. www.tamaracksolar.com All installers must thoroughly read this manual and have a clear understanding of the installation procedures prior to installation.
  • Page 3 Pole Mount - TTP Series Pole Mount - TTP Series TTP-Series Pole Mount Components Part # Part Description TTP 4 TTP 4HW TTP 6 TTP 6HW 92062 Pole Cap, Pivot 6 inch pipe, 2.5 inch holes 92063 Pole Cap 6 inch Backplate...
  • Page 4 Pole Mount - TTP Series Foundation Hole and Pole Guidelines • Th e suggestions below are recommendations only. It is the installer’s responsibility to validate foundation parameters prior to installation, a local geotechnical report may be required to assess soil conditions. We...
  • Page 5 Pole Mount - TTP Series TTP 4 and TTP 4HW for Array Ground Clearance of 3 Feet Foundation Hole Depth, Height of Pole Above Ground and Total Pole Length for Ground Clearance of 3 Feet at Lowest Part of the Array & Exposure Catgory B For Various Soil Class and Foundation Hole Diameter. Vertical Pipe is 6-inch Schedule 40...
  • Page 6 Pole Mount - TTP Series TTP 6 and TTP 6HW for Array Ground Clearance of 3 Feet Foundation Hole Depth, Height of Pole Above Ground and Total Pole Length for Ground Clearance of 3 Feet at lowest part of the array &...
  • Page 7 Pole Mount - TTP Series Step One - Pole Cap Assembly • Place the Pole Cover on top of the mounting pole. • Put the 3/4 x 9-inch Cap Support Bolt through the two top holes in the rear half of the Pole Cap and install nut and tighten fi rmly.
  • Page 8 Pole Mount - TTP Series Step Three - Assemble Adjuster Arm • Attach the Adjuster Arm to the Adjuster Pipe with a 2-3/8-inch U-bolt and two ange nuts as pictured at right. Tighten hand tight for now. • Using the hole in the Adjuster...
  • Page 9 Pole Mount - TTP Series Step Five - Module Mounting Rail Assembly • For TTP-4 and TTP-4HW Mounts, use the 85-inch long Module Mounting Rails provided. • For the TTP-6 and TTP-6HW mounts, assemble four 127.5-inch Module Mounting Rails as follows: 1) Splice one 85-inch rail and one 42.5 rail together using the provided Splice...
  • Page 10 Pole Mount - TTP Series • Place one of the Module Mounting Rails on two of the Pipe Mounts installed on the Rail Support Pipes, center it in the north/south direction so it extends past both Support Pipes the same distance. Make sure that the Pipe Mount slips into both of the mounting features on the bottom of the rails (see drawing at right).
  • Page 11: Final Assembly

    Pole Mount - TTP Series • Start module installation at the bottom of the fi rst column. Measure up the rail by by 1/2 of the distance calculated in #2 above. Place a Module Clamp on each of the Module Mounting Rails at this distance.