Summary of Contents for Tamarack Solar Ground Roof Mount Series
Page 1
Ground Roof Installation Manual Mount Series Installation Manual UNI-GR Manual v3 Formodels: Panel Support length UNI-GR/90 90” UNI-GR/130 130” The picture at rtight shows the rear view of 2 of the UNI- GR mounts connected with the optional intertie kit.
Customer Support Tamarack Solar makes every effort to ensure your m ounting kit is easy to install. If you need assistance at any point in your installation or have suggestions on how we can improve your experience, call customer support at 1-800-819-7236 ext 556 or email us at support@tamaracksolar.com.
Page 3
Ground Roof Installation Manual Mount Series Components List The following parts are included with the GR mounts Part # Description UNI-GR/90 UNI-GR/130 51-0627-003 Channel Connector 51-0545-001 Panel Support Channel - 45-inch 51-0565-001 Panel Support Channel - 65-inch 51-0546-000 Inner Brace Channel - 46-inch 51-0546-001 Outer Brace Channel - 46-inch 51-6000-003...
Ground Roof Installation Manual Mount Series Pre Assembly Step 1: Connect Panel Support Channels A. Slide the 10” connector halfway into the end of the one of the panel support and install the 5/16” hardware, Torque to 132 in-lbs. repeat with the second panel support to achieve the overall panel support length B.
Ground Roof Installation Manual Mount Series Step 2: Determine foot spacing There are many combinations of bolting locations and brace overlap configurations to achieve foot spacing’s for the angle(s) desired for your location, the following is a process to make that determination to fit your requirements, or use the general specification chart on page 5.
Ground Roof Installation Manual Mount Series General specification chart The tables below are suggested front to back foot spacing “E” with the tilt angles that can set at that spacing. “A” is module tilt angle from the horizontal, “C” is the overlap of the back leg sections and “D” is the distance from the top of the module mounting rail to the hole used to connect the back leg.
Ground Roof Installation Manual Mount Series Step 3: Foot attaching options Use Galvanized or Stainless-Steel Hardware See Suggestions below: Page 6 support@tamaracksolar.com 1-800-819-7236 Ext 556...
Ground Roof Installation Manual Mount Series Step 4 Attaching PV modules to panel supports A. Lay the PV Modules face-down on a protected flat surface mounting hole side up. B. Lay the flat side of the panel support channels across the panels keeping panels and supports parallel.
Ground Roof Installation Manual Mount Series Final Assembly Step: 1 Attach U-foot to footings A. Attach the U-foot and backing plate to your footings, align the feet east\west and north\south and torque 3/8-16 galvanized hardware to 16 ft-Lbs. (Concrete footings shown) Space between mounts Step 2: Attach Preassembled rear braces to footings.
Ground Roof Installation Manual Mount Series Step 3: Attach Pre-Assembled Panel array to footings. A. Loosely attach one end of the Panel assembly to the U-feet on the footings. Step 4: Attach rear braces to panel supports A. Tilt up the array, and the rear braces, and bolt the rear leg into the hole chosen at the distance on step 2 of “Determine foot spacing”...
Ground Roof Installation Manual Mount Series OPTIONAL UNI-GR Intertie Installation 51-0520-005 If you are installing 2 or more UNI-GR mounts, you can tie them together to increase stability by putting one of the UNI-GR intertie kits between each mount. This brace is adjustable from 18.25” to 32”...
Tamarack Solar by Purchaser, any employee of Purchaser, client of Purchaser, end-user of the Product or other party, even if Tamarack Solar has been advised of the possibility of such claims or demands (collectively, “Third Party Claims”). This limitation applies to all materials provided by Tamarack Solar during and after the Warranty Period.