To ensure the best results from this unit please take the time to read and follow all safety, installation and maintenance guidelines carefully before proceeding to install. Keep this manual in a safe place for future consultation. These appliances are marked in compliance with the relevant regulations Voltage stated on unit data plate.
1: Electrical Specification This appliance must be earthed and damaged cables must be replaced by a suitably qualified person! 1 Phase Cable 3 Phase Cable Live (L1) Brown Brown Black Grey Neutral Blue Blue Earth Yellow & Green (Striped) Yellow & Green (Striped) A mains cable, type H07RN-F, conforming to code designation 60245 IEC 57, is supplied.
3: General Installation Before installation please read the following points: • When placing in position ensure there is adequate access. • These mobile units can simply be butted up together to form a food service line. • Roll into position and apply the brakes. •...
4: Installation conditions model HH1C Refrigerated Unit Venting When installing these refrigerated units, allowances must be made for air venting. It is crucial that there is an unrestricted air flow through the under slung compressor and condensing coil. Proper venting must be provided ensuring cool air from the room can be pumped in through the condensing coil and out the other side.
Page 6
Should conditions exceed the above, the display units may not maintain food temperatures at the required levels. E & R Moffat cannot accept responsibility for the performance of the units being used in extreme conditions. Do not install units where there is high radiated heat,e.g. direct sunlight, room heaters, or bright spot lights.
Refrigerated Units 5: Operation model HH1C Refrigerated display units are designed to keep pre-chilled food at a regulated serving temperature and are suitable for the display of most types of cold food. Designed to provide a chilled condition maintaining a safe and compliant temperature within. The Chilled display has an automatic defrost, and automatic condensate water evaporation system, eliminating the need to manually empty drip trays or onsite drainage.
5: Operation model HH1H Heated display units are designed to keep pre-heated food at a regulated serving temperature and are suitable for the display of most types of hot food. Designed with individually controlled shelves maintaining a safe and compliant temperature within. These units are not designed to cook or heat up cold food Control are positioned on the rear of the unit Operation:...
Page 9
5: Operation model HH1H The rotary temperature control are located on the rear of the units. The temperature can be set for each shelf.
11: Cleaning 7: Cleaning Before attempting to clean the unit, please ensure that the Unit is isolated from the electric supply and allowed to cool down, with all food plates and other Dishes removed from the unit. Do not use a water jet or pressure spray to clean this appliance. Disconnect trolley from mains and wait until appliance has cooled.